Operating Instruction Manual

  

Elektroblock EBL 263-5  Art no 911.056

 

 

page 7 

/

 10

 

Note: this operating instruction manual is intended for the customer and has to be supplied with the device 

 

Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de  18.05.2004

 

refrigerator relay 

This relay controls the power supply of the absorption-type refrigerator. 
The refrigerator is powered by the starter battery but only, when the engine 
is running and when there is a voltage on terminal 'D+'. 

charging relay  

This relay automatically provides a 2A trickle-charge to the starter battery 

starter battery 

when the EBL is connected to mains supply. 

3.4 Battery 

Monitor 

The battery monitor compares the voltage of the living-area battery with a reference voltage.  

As soon as the battery voltage falls below 10.5 V, all 12V load is switched off (except the automatic 
step). Short falls (< 2 sec ) below the threshold voltage, due to high inrush currents of connected load, 
do not affect the automatic cut-off function. 

If the automatic shut-down has been triggered due to overload or an insufficiently charged battery, all 
non-essential load should be switched off. 

By actuating the 

12V

 push-button switch on the front panel it may be possible to reactivate the 12V- 

system for a short period of time. 

However, the 12 V system cannot be switched on if the battery voltage stays under 11.0V. 

In any case, the living-area battery should be fully recharged as soon as possible. 

4. 

Transport, Storage, Installation 

4.1 Transport, 

Storage 

*  The EBL should be stored and transported in a suitable packing and in a dry environment only. 

*  Storage temperature range : - 20°C to + 70°C. 

4.2 Installation 

*  The EBL has been designed for use in a dry and sufficiently ventilated environment within a 

temperature range of  - 10°C to + 40°C.  

*  The EBL is designed to be fitted in a cabinet front . A minimum distance of 5 cm to the surrounding 

equipment has to be maintained above and to all sides. 
In operation a temperature of max. + 40°C in a distance of 2.5 cm has to be maintained. 

 

Caution !

 

Danger of overheating if distances to equipment are too short or if ventilation is blocked. 

 

*  The EBL has to be fitted on a solid and level surface by use of the four provided fixing holes. 

It has to be seated on its bottom side without blocking the ventilation. 
Please refer to the enclosed table of measures EBL 263-5 for permitted seating details.

 

5. Electrical 

Installation 

*  Electrical installation has to be executed by qualified personnel only. 

*  The device must be used only with a connected living-area battery. 

 

Caution !

 

The Elektroblock must not be used without a connected living-area battery, otherwise 
connected appliances might be damaged in unfavourable conditions.

 

*  The electrical connection is made on the back according to the enclosed schematic diagram. 

Summary of Contents for 911.056

Page 1: ...ol the living area functions of the motor home and indicate certain values like voltages or filling levels Tank sensors are necessary to measure the filling levels of the water tanks Please do order separately Note The EBL 263 5 is not suitable for filling level measurement of metal water tanks 1 1 Suitable Accessories rod tank sensors 2 rod tank sensors 2 sensor cables 4 x 0 5 2 seal rings art no...

Page 2: ...charge at constant 14 4V selectable 20 minutes duration for lead acid 6h duration for lead gel batteries U then automatic change over to float charge at 13 8V If due to high loads the float voltage of 13 8V cannot be provided the battery charger switches over from float to boost charge safety circuits short circuit and reverse polarity protected charger needs a connected battery with a voltage of ...

Page 3: ...d must be conform to specifications mentioned in this operating instruction manual see instruction manual section 4 2 Installation section 5 Electrical Installation and in enclosure schematic diagram of EBL 263 5 In the following text special notice should be paid to the signs shown below Caution Electrical current hazard warning Caution General hazard warning 3 Operating Instructions 3 1 Controls...

Page 4: ... hours Low charging current or 12V system overloaded green 12 3V Battery properly charged Standard charge Standard charge Low voltage warning indicator Optical warning of a alarming low living area battery charge As soon as the living area battery voltage drops below 10 8V the red warning light starts blinking Any load must now be switched off immediately and the living area battery should be rech...

Page 5: ...s shown Actuate switch in direction of Filling level of waste water tank is shown LED with symbol is on water tank full LED with symbol is on water tank approx half full LED with symbol is on water tank approx a quarter full No LED indication water tank empty Note Inquiry of water tank filling levels is for temporary use only The used method of measurement is not suitable for continuous operation ...

Page 6: ...ws at each corner of the front panel and pull out the device Disconnect all positive poles of each of the seven consumer circuits label each one well Insert a new main fuse Caution danger of burning Better disconnect the positive battery terminal first If the fuse blows again the main circuit of the battery is at fault otherwise Actuate 12V switch on front panel of EBL 263 5 the green LED must lig...

Page 7: ...rt period of time However the 12 V system cannot be switched on if the battery voltage stays under 11 0V In any case the living area battery should be fully recharged as soon as possible 4 Transport Storage Installation 4 1 Transport Storage The EBL should be stored and transported in a suitable packing and in a dry environment only Storage temperature range 20 C to 70 C 4 2 Installation The EBL h...

Page 8: ...act junction box The device must be used exclusively in vehicles equipped with an easily accessible cut out eg a circuit breaker in the wardrobe 5 2 Batteries and D Alternator The battery is connected by a 3 pole EURO terminal The alternator control signal D is connected to terminal 6 of the 6 pole plug in screw terminal water tank 2 waste water Cable size dimensions have to be in accordance with ...

Page 9: ...type selector switch See section 3 1 Controls 6 2 Shut Down Before and after shut down eg winter recess the battery should be fully recharged Connect the motor home to mains supply and charge the battery for a minimum of 16 hours 80Ah battery or 24 hours 160Ah battery Before long periods of disuse the motor home battery should be disconnected from the 12V system Take off terminals at battery poles...

Page 10: ...ore not liable to resulting damages 8 Enclosure To this operating instruction manual belongs the enclosed schematic diagram the table of measurement and front and back view drawings of the Elektroblock EBL 263 5 art no 911 056 This operating instruction manual with all its enclosures must be delivered together with the energy management system Elektroblock EBL 263 5 art no 911 056 It has to be par...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: