Operating Instruction Manual

  

Elektroblock EBL 263-5  Art no 911.056

 

 

page 8 

/

 10

 

Note: this operating instruction manual is intended for the customer and has to be supplied with the device 

 

Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de  18.05.2004

 

*  For installation purposes, the mains plug or the mains supply of the vehicle must be disconnected. 

 

Caution !

 

Danger of life due to electrical shock or danger of burning with a defective mains  
cable, incorrect connection or service with mains supply on. 

*  Please note: all installation must be carried out with disconnected batteries. 

*  The electrical connection has to be in accordance to the following sequence: 
  1. 

12V consumers, D+ (alternator) and water-tank connections 

  2. 

battery cables at EBL 

  3. 

battery cables at battery terminals 

  4. 

230V mains connection 

*  Disconnection has to be executed vice versa. 

5.1 

230V Mains Supply 

*  The mains cable on the back of the device is strain-relieved. Its ends are push-on contacts 6.3 x 0,8.   

*  Mains supply has to be connected to a insulated earthing-contact junction box.  

*  The device must be used exclusively in vehicles equipped with an easily accessible cut-out, eg a  

circuit breaker in the wardrobe. 

5.2 

Batteries and D+ (Alternator) 

*  The battery is connected by a 3-pole EURO terminal. 

  The alternator control signal D+, is connected to terminal 6 of the 6-pole plug-in screw terminal 

('water tank 2, waste water'). 

*  Cable size dimensions have to be in accordance with European norm EN 1648-1 or –2.

 

*  Leads have to be fused according to their cross-sections.

 

Maximum allowed fuse ratings: 

Batteries 

D+ (Alternator) 

 30A 

2A 

*  The fuses need to be installed close the battery terminals for short circuit protection of the leads  

and alternator. 

*  The negative pole of the living-area battery has to be connected to the negative pole of the starter  

battery externally. 

 

Caution !

 

Danger of burning with incorrect connection and fusing. 

*  The EBL has to be used exclusively on 12V power systems with rechargeable 6-cell lead-acid or  

lead-gel batteries. 

 

Caution ! 

Unsuitable batteries will be damaged. 

*  Batteries have to be installed in sufficiently ventilated areas or must have integrated venting. 

Please refer to installation instructions of the battery manufacturer.  

 

Caution !

 

Exploding hazard

 by detonating gas with defective batteries, defective Elektroblock 

or at too high battery temperature (> 30°C). 

Summary of Contents for 911.056

Page 1: ...ol the living area functions of the motor home and indicate certain values like voltages or filling levels Tank sensors are necessary to measure the filling levels of the water tanks Please do order separately Note The EBL 263 5 is not suitable for filling level measurement of metal water tanks 1 1 Suitable Accessories rod tank sensors 2 rod tank sensors 2 sensor cables 4 x 0 5 2 seal rings art no...

Page 2: ...charge at constant 14 4V selectable 20 minutes duration for lead acid 6h duration for lead gel batteries U then automatic change over to float charge at 13 8V If due to high loads the float voltage of 13 8V cannot be provided the battery charger switches over from float to boost charge safety circuits short circuit and reverse polarity protected charger needs a connected battery with a voltage of ...

Page 3: ...d must be conform to specifications mentioned in this operating instruction manual see instruction manual section 4 2 Installation section 5 Electrical Installation and in enclosure schematic diagram of EBL 263 5 In the following text special notice should be paid to the signs shown below Caution Electrical current hazard warning Caution General hazard warning 3 Operating Instructions 3 1 Controls...

Page 4: ... hours Low charging current or 12V system overloaded green 12 3V Battery properly charged Standard charge Standard charge Low voltage warning indicator Optical warning of a alarming low living area battery charge As soon as the living area battery voltage drops below 10 8V the red warning light starts blinking Any load must now be switched off immediately and the living area battery should be rech...

Page 5: ...s shown Actuate switch in direction of Filling level of waste water tank is shown LED with symbol is on water tank full LED with symbol is on water tank approx half full LED with symbol is on water tank approx a quarter full No LED indication water tank empty Note Inquiry of water tank filling levels is for temporary use only The used method of measurement is not suitable for continuous operation ...

Page 6: ...ws at each corner of the front panel and pull out the device Disconnect all positive poles of each of the seven consumer circuits label each one well Insert a new main fuse Caution danger of burning Better disconnect the positive battery terminal first If the fuse blows again the main circuit of the battery is at fault otherwise Actuate 12V switch on front panel of EBL 263 5 the green LED must lig...

Page 7: ...rt period of time However the 12 V system cannot be switched on if the battery voltage stays under 11 0V In any case the living area battery should be fully recharged as soon as possible 4 Transport Storage Installation 4 1 Transport Storage The EBL should be stored and transported in a suitable packing and in a dry environment only Storage temperature range 20 C to 70 C 4 2 Installation The EBL h...

Page 8: ...act junction box The device must be used exclusively in vehicles equipped with an easily accessible cut out eg a circuit breaker in the wardrobe 5 2 Batteries and D Alternator The battery is connected by a 3 pole EURO terminal The alternator control signal D is connected to terminal 6 of the 6 pole plug in screw terminal water tank 2 waste water Cable size dimensions have to be in accordance with ...

Page 9: ...type selector switch See section 3 1 Controls 6 2 Shut Down Before and after shut down eg winter recess the battery should be fully recharged Connect the motor home to mains supply and charge the battery for a minimum of 16 hours 80Ah battery or 24 hours 160Ah battery Before long periods of disuse the motor home battery should be disconnected from the 12V system Take off terminals at battery poles...

Page 10: ...ore not liable to resulting damages 8 Enclosure To this operating instruction manual belongs the enclosed schematic diagram the table of measurement and front and back view drawings of the Elektroblock EBL 263 5 art no 911 056 This operating instruction manual with all its enclosures must be delivered together with the energy management system Elektroblock EBL 263 5 art no 911 056 It has to be par...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: