Instruction Manual Electrobloc EBL 208 S G

R

6 Operation

6.1 Operating controls

Flat vehicle fuses

The flat vehicle fuses protect the various circuits. When necessary, take off 
the blue cover marked "FUSE" (optional) and check or change the fuses.

Battery cut-off switch

The battery cut-off switch "Battery on/off" disconnects the following connec-
tions from the living area battery:

all 12 V consumers except the AES refrigerator and the entrance step

the frost protection valve

the control and switch panel

This prevents the living area battery from slowly discharging due to closed cir-
cuit current while the vehicle is not in use.
The batteries can still be charged using the Electrobloc, the alternator or the 
solar charge regulator, even when the battery cut-off switch is switched off.

To start the system, set the battery cut-off switch to "Battery on".

To shut down the system, set the battery cut-off switch to "Battery off".

Starter battery

Charging current

Float charge of starter battery at 
max. 2 A

Battery charging via solar

charge regulator

Only the living area battery is charged.

Maximum charging current

14 A, fuse-protected by 15 A fuse

Battery charging while

travelling

Simultaneous charging of the starter battery and the living area battery by the 
alternator
Batteries connected in parallel via a cut-off relay

Battery monitor

Breaking voltage

Approx. 10.5 V

Minimum battery voltage for 
switching on via 12 V main 
switch on the control panel

Approx. 11.0 V

Blown fuses must only be replaced when the cause of the fault is 
known and eliminated.

Never bridge or repair fuses.

Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.

Only use original fuses rated as specified in the instruction manual.

The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.

Summary of Contents for Electrobloc EBL 208 S G

Page 1: ...Instruction manual Electrobloc EBL 208 S G Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Suitable accessories not supplied 4 5 Technical data 4 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 8 10 Technical faults possible causes and remedies 9 11 Customer service 10 12 Block diagram for specialist workshop only 11...

Page 2: ...Electrobloc must be dealt with immediately by qualified personnel Failure to comply with this sign may lead to the endangerment of per sons Failure to comply with this sign may damage the unit or the connected con sumers This sign indicates recommendations or special features The electrical system of the motorhome or the caravan has to meet cur rent DIN VDE and ISO regulations Manipulations of the...

Page 3: ...ges the living area battery Disconnect the Electrobloc from the mains before adjusting the battery selector switch When the living area battery is separated from the Electrobloc by the bat tery cut off switch the frost protection valve of the heater system opens Before and after shutdown the living area battery must be fully recharged to avoid battery damage For this purpose the vehicle must be co...

Page 4: ...106 120 5 Technical data Int Charger 20A 6 3 19 13 7 4 5 Lead Acid 1 to Panel 15A AES 2 1 Battery Type Lead Gel AGM 1 Solar Regulator 10 16 22 21 15 9 20 14 8 23 17 11 24 18 12 1 3 7 5A 2 10A 1 10A 15A 10A Reserve 7 5A 5A 15A 20A 230V AC off on Battery ELEKTROBLOCK EBL 208 S Do not touch side gets hot Caution Rear with AES Fuse only refrigerator Pb Accu 55Ah 230V 50Hz T 45 B 1 9A i IUoU 3 15AT 18A...

Page 5: ...itch to Battery on To shut down the system set the battery cut off switch to Battery off Starter battery Charging current Float charge of starter battery at max 2 A Battery charging via solar charge regulator Only the living area battery is charged Maximum charging current 14 A fuse protected by 15 A fuse Battery charging while travelling Simultaneous charging of the starter battery and the living...

Page 6: ... light only works when the power supply is on the vehicle engine is off and the D connection is not live Automatic switch function for refrigerator This relay supplies the refrigerator with power from the starter battery when the vehicle engine is running and the D connection is live An AES refriger ator is powered by the living area battery when the vehicle engine is switched off Mains charging o...

Page 7: ...hinners or similar substances Do not allow fluid to penetrate the inside of the Electrobloc 8 Shutting down the system Disconnecting the living area battery from the 12 V power supply Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a lengthy period for example during the win ter Switch off the 12 V main switch on the control and switch pa...

Page 8: ...on After having disconnected the living area battery from the Electrobloc using the battery cut off switch or after changing the battery briefly switch on the 12 V main switch on the control and switch panel to start up the con sumers Batteries may only be changed by qualified personnel Follow the instructions of the battery manufacturer To electrically disconnect the battery from the Electrobloc ...

Page 9: ...tery is not charged during 230 V operation battery voltage constantly below 13 0 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living area battery is not charged during mobile operation battery voltage below 13 0 V Defective alternator Have the alternator checked No voltage at D input Have the fuse and wiri...

Page 10: ...wer supply in the living area does not work 12 V main switch for the liv ing area battery is switched off Switch on the 12 V main switch for the living area battery Battery cut off switch turned off Switch on the battery cut off switch Defective fuse or wiring Have the fuse and wiring checked Defective Electrobloc Call customer service Fault Possible cause Remedy If the device becomes too hot due ...

Page 11: ... V off 12 V on 12 V indicator Shunt consumer Starter battery Living area battery sensor Shunt battery Battery cut off switch 6 3x0 8 4x 6x Plug connector LF PA 401 30A 2A 30A 2A 30A Negativelivingareabatterysensor Living area battery sensor Negative living area battery Negative living area battery D base D input Starter battery Living area battery Battery monitor module BW 208 6 9 10 7 3 1 2 8 5 4...

Page 12: ...ompleted fault report There is the following defect please tick Other remarks Device type Type no EBL 208 S G _________________ Battery not being charged during power operation Battery not being charged during mobile operation Following electri cal consumers do not work Malfunction of control and switch panel Tank Voltage Current Constant fault Temporary fault loose contact ...

Reviews: