6.3 Battery monitor

Automatic disconnector

The battery monitor compares the voltage of the living area battery to a refer-
ence voltage. As soon as the battery voltage falls below 10.5 V, all 12 V con-
sumers are switched off. Only the entrance step, the frost protection valve and 
the AES refrigerator are still powered. The automatic disconnector is not trig-
gered by short-term low voltage (less than 2 seconds), caused by high current 
when switching on consumers.
If overload or an insufficiently charged living area battery causes the voltage 
to fall so low that the automatic disconnector is triggered, any consumers 
which are not essential should be switched off.
You may be able to switch on the 12 V power supply for a short time. To do 
this, switch on the 12 V main switch on the control and switch panel.
However, if the battery voltage remains below 11.0 V, you cannot switch on 
the 12 V power supply.
Fully charge up the living area battery as soon as possible. For more informa-
tion see the description of battery voltage.

7 Maintenance

The Electrobloc EBL 208 S G requires no maintenance.

Cleaning

Clean the Electrobloc with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances.
Do not allow fluid to penetrate the inside of the Electrobloc.

8 Shutting down the system

Disconnecting the living

area battery from the

12 V power supply

Disconnect the living area battery from the 12 V power supply if you are not 
going to use the motorhome for a lengthy period (for example during the win-
ter).

Switch off the 12 V main switch on the control and switch panel.

Set the battery cut-off switch on the Electrobloc to "Battery off".

On the solar charge regulator, pull out the "+ Solar cell" plug if you are 
going to remove the battery.

Pull out the fuse for the AES refrigerator.

When the living area battery is separated from the Electrobloc by the bat-
tery cut-off switch, the frost protection valve of the heater system opens. 
Water may be lost.

Before and after shutdown, the living area battery must be fully recharged 
to avoid battery damage. For this purpose the vehicle must be connected 
to mains supply for a minimum of 12 hours with an 80 Ah battery and 
16 hours with a 160 Ah battery.

Do not operate the Schaudt solar charge regulator without a battery. This 
might damage the solar charge regulator or any connected consumers. If 
the battery is going to be changed or removed, please first take off the pos-
itive lead "+ Solar Module" on the solar charge regulator.

The living area battery can also be charged using the internal charger 
module, the solar charge regulator and the alternator when the battery cut-
off switch is switched off.

Summary of Contents for Electrobloc EBL 208 S G

Page 1: ...Instruction manual Electrobloc EBL 208 S G Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Suitable accessories not supplied 4 5 Technical data 4 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 8 10 Technical faults possible causes and remedies 9 11 Customer service 10 12 Block diagram for specialist workshop only 11...

Page 2: ...Electrobloc must be dealt with immediately by qualified personnel Failure to comply with this sign may lead to the endangerment of per sons Failure to comply with this sign may damage the unit or the connected con sumers This sign indicates recommendations or special features The electrical system of the motorhome or the caravan has to meet cur rent DIN VDE and ISO regulations Manipulations of the...

Page 3: ...ges the living area battery Disconnect the Electrobloc from the mains before adjusting the battery selector switch When the living area battery is separated from the Electrobloc by the bat tery cut off switch the frost protection valve of the heater system opens Before and after shutdown the living area battery must be fully recharged to avoid battery damage For this purpose the vehicle must be co...

Page 4: ...106 120 5 Technical data Int Charger 20A 6 3 19 13 7 4 5 Lead Acid 1 to Panel 15A AES 2 1 Battery Type Lead Gel AGM 1 Solar Regulator 10 16 22 21 15 9 20 14 8 23 17 11 24 18 12 1 3 7 5A 2 10A 1 10A 15A 10A Reserve 7 5A 5A 15A 20A 230V AC off on Battery ELEKTROBLOCK EBL 208 S Do not touch side gets hot Caution Rear with AES Fuse only refrigerator Pb Accu 55Ah 230V 50Hz T 45 B 1 9A i IUoU 3 15AT 18A...

Page 5: ...itch to Battery on To shut down the system set the battery cut off switch to Battery off Starter battery Charging current Float charge of starter battery at max 2 A Battery charging via solar charge regulator Only the living area battery is charged Maximum charging current 14 A fuse protected by 15 A fuse Battery charging while travelling Simultaneous charging of the starter battery and the living...

Page 6: ... light only works when the power supply is on the vehicle engine is off and the D connection is not live Automatic switch function for refrigerator This relay supplies the refrigerator with power from the starter battery when the vehicle engine is running and the D connection is live An AES refriger ator is powered by the living area battery when the vehicle engine is switched off Mains charging o...

Page 7: ...hinners or similar substances Do not allow fluid to penetrate the inside of the Electrobloc 8 Shutting down the system Disconnecting the living area battery from the 12 V power supply Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a lengthy period for example during the win ter Switch off the 12 V main switch on the control and switch pa...

Page 8: ...on After having disconnected the living area battery from the Electrobloc using the battery cut off switch or after changing the battery briefly switch on the 12 V main switch on the control and switch panel to start up the con sumers Batteries may only be changed by qualified personnel Follow the instructions of the battery manufacturer To electrically disconnect the battery from the Electrobloc ...

Page 9: ...tery is not charged during 230 V operation battery voltage constantly below 13 0 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living area battery is not charged during mobile operation battery voltage below 13 0 V Defective alternator Have the alternator checked No voltage at D input Have the fuse and wiri...

Page 10: ...wer supply in the living area does not work 12 V main switch for the liv ing area battery is switched off Switch on the 12 V main switch for the living area battery Battery cut off switch turned off Switch on the battery cut off switch Defective fuse or wiring Have the fuse and wiring checked Defective Electrobloc Call customer service Fault Possible cause Remedy If the device becomes too hot due ...

Page 11: ... V off 12 V on 12 V indicator Shunt consumer Starter battery Living area battery sensor Shunt battery Battery cut off switch 6 3x0 8 4x 6x Plug connector LF PA 401 30A 2A 30A 2A 30A Negativelivingareabatterysensor Living area battery sensor Negative living area battery Negative living area battery D base D input Starter battery Living area battery Battery monitor module BW 208 6 9 10 7 3 1 2 8 5 4...

Page 12: ...ompleted fault report There is the following defect please tick Other remarks Device type Type no EBL 208 S G _________________ Battery not being charged during power operation Battery not being charged during mobile operation Following electri cal consumers do not work Malfunction of control and switch panel Tank Voltage Current Constant fault Temporary fault loose contact ...

Reviews: