8110600 BA / EN
Edition: 20.11.2018
9
Instruction Manual Electrobloc EBL 208 S G
R
10 Technical faults, possible causes and remedies
If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, for example if you are abroad, you can have the Elec-
trobloc repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.
Fault
Possible cause
Remedy
Living area battery is not
charged during 230 V
operation (battery voltage
constantly below 13.3 V)
No mains voltage
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc
Call customer service
The living area battery is
overloaded during 230
operation (battery voltage
in the red zone on the com-
bined measuring instru-
ment)
Defective Electrobloc
Call customer service
Starter battery is not
charged during 230 V
operation (battery voltage
constantly below 13.0 V)
No mains voltage
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc
Call customer service
Living area battery is not
charged during mobile
operation (battery voltage
below 13.0 V)
Defective alternator
Have the alternator
checked
No voltage at D+ input
Have the fuse and wiring
checked
Defective Electrobloc
Call customer service
The living area battery is
overloaded during mobile
operation (battery voltage
in the red zone on the com-
bined measuring instru-
ment)
Defective alternator
Have the alternator
checked
The refrigerator does not
work during mobile opera-
tion
No power supply to the
refrigerator
Have the fuse and wiring
checked
Defective Electrobloc
Call customer service
Defective refrigerator
Have the refrigerator
checked
Solar charger does not
work (power supply and
engine are off)
Solar charge regulator not
plugged in
Plug in the solar charge
regulator
Defective fuse or wiring
Have the fuse and wiring
checked
Defective solar charge reg-
ulator
Have the solar charge reg-
ulator checked