Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP

8

Date: 15.10.2018

8110305 BA / EN

4.1

Battery functions

6-cell lead-gel or AGM batteries, 55 Ah and above

Simultaneous charging of the starter battery and the living area battery via

the alternator, parallel connection of the batteries via a cut-off relay

Maximum permitted charge current 14 A, fused with 15 A (for leisure area

battery), simultaneous charging of the starter battery

The battery is isolated with the battery cut-off switch.

This prevents the living area battery from slowly discharging due to closed

circuit current while the vehicle is not in use.

The switching option provided by the battery selector switch ensures opti-

mum charging of the battery types, lead-gel and AGM, for mains supply.

The battery monitor compares the current of the living area battery with a

reference current. As soon as the battery current drops below 10.5V, all 12V

consumers are switched off via main switch relays 1 and 2.

Only the frost protection valve continues to be powered.

The automatic disconnector is not triggered by short-term low voltage (shor-

ter than 2 seconds), caused by high current when switching on consumers.

If an overload or an insufficiently charged living area battery causes the vol-

tage to fall so low that the automatic disconnector is triggered, any non-es-

sential consumers should be switched off.

If need be, the 12V supply can begin operation for a short time. For this,

switch on the 12V main switch on the control and switch panel.

However, if the battery current remains below 11.0V, the 12V supply can not

be switched on again. Fully charge the living area battery as soon as possi-

ble. For more information, see the description of ”battery voltages”.

Suitable batteries

Battery charging

whilst moving

Battery charging via

solar charge regulator

Battery isolation

Battery selector switch

Automatic disconnector

Summary of Contents for Electroblock EBL 30

Page 1: ...ty information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Starting up the system 3 3 2 Changing the battery 4 3 3 Operating faults 5 3 4 Closing down the system 6 4 Application and functions in detail 7 4 1 Battery functions 8 4 2 Additional functions 9 5 Technical details 9 5 1 Mechanical details 9 5 2 Electrical details 9 5 3 Environment...

Page 2: ...cting the safety of individuals or the proper functioning of the device must be repaired immediately by specialists Y DANGER 230V units carrying mains voltage Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate it from the power supply F Ensure that no liqui...

Page 3: ...ronic installations at cam ping sites For this an overvoltage protection unit is fitted in the electroblock between the mains connection and the charge module In the event of over or under voltage this overvoltage protector isolates the electroblock from the 230V supply within just a few milliseconds It remains cut off until the main voltage has normal values again 3 1 Starting up the system Y ATT...

Page 4: ...y isolate the battery from the electroblock For this switch off the battery separation switch on the EBL 30 electroblock refer also to Section 3 4 Replace the battery After changing the battery recheck which type of battery has been inser ted Y DANGER Incorrect setting of the battery selector switch Risk of explosion due to build up of explosive gases F Move the battery selector switch to the corr...

Page 5: ...tact customer service Starter battery is not char d d i 230V No mains voltage Switch on the automatic i i b k i h hi y ged during 230V opera tion battery voltage con g circuit breaker in the vehi cle check the mains vol tion battery voltage con stantly below 13 0 V cle check the mains vol tage y Too many consumers are switched on Switch off any consumers not required Defective electroblock Contact...

Page 6: ...em The battery is isolated by switching off the battery cut off switch Y ATTENTION Total discharge Damage to the leisure area battery F Fully charge the living area battery before and after closing down the system Connect vehicle to the mains with an 80Ah battery at least 12 hours and with a 160Ah battery at least 24 hours Disconnect the living area battery from the 12V power supply if the motor h...

Page 7: ...eries connected F the complete 12V distribution system F fuses for the 12V circuits F a battery monitoring module F control and monitoring functions An IT or LT control and switch panel must be connected for operation These devices control the electrical functions in the vehicle s living area inc luding accessories There is also an option to connect an additional charger and a solar loading regula...

Page 8: ...eference current As soon as the battery current drops below 10 5V all 12V consumers are switched off via main switch relays 1 and 2 Only the frost protection valve continues to be powered The automatic disconnector is not triggered by short term low voltage shor ter than 2 seconds caused by high current when switching on consumers If an overload or an insufficiently charged living area battery cau...

Page 9: ...d light grey RAL 7035 5 2 Electrical details 230V AC 10 47 63 Hz sinusoidal protection class I 1 9 A 6 cell lead gel or AGM batteries 55 Ah and above Dependent on the control panel approx 5 20 mA plus consumption of controller electronics of refrigerator Conditions for the measurement F approx 10 minutes after disconnection from the mains F 12 6 V battery voltage F Battery alarm OFF F Battery cut ...

Page 10: ...rt of charge also for completely discharged batteries Uo Automatic switchover to full charge with constant 14 4 V lead gel or 14 7 V AGM The duration of the full charge phase is based on the battery type and is set on the device U Automatic changeover to compensation charge with constant 13 7 V In the compensation charge phase the voltage at the output of the char ging module is constant Start of ...

Page 11: ...0 electroblock requires no maintenance Clean the electroblock with a soft slightly damp cloth and mild detergent Never use spirit thinners or similar substances Do not allow liquids to enter the electroblock No part of this manual may be reproduced translated or copied without ex press written permission Cleaning E ...

Page 12: ... display panel required for operation Schaudt battery charger LAS with max 18 A charge current including suitable connection cable MNL Schaudt Solar charge regulator type LR for solar modules with a total cur rent of 14A with 3 pole connection plug and connection cable C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany Phone 49 7544 9577 16 Email kunde...

Page 13: ...o the manufacturer Device type _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Persistent fault Intermittent fault loose contact Other comments...

Page 14: ...control lines 5 Connection block frost protection valve heating and floor light steps 6 IT LT control and display panel connector 7 Connection block spare 2 sockets 2 floor light 4A and 4B radio 8 Connection block additional charger 9 Connection block TV pump sockets 1 spare 1 circuits 1 and 2 10 Lead gel AGM battery changeover switch 11 Flat vehicle fuses 12 Battery cut off switch 13 Housing 14 A...

Page 15: ... battery must be connected externally to the negative terminal of the starter battery rear Black Positive living area battery 50 A Red External fuse maxi fuse 6 Mains indicator 4 Shunt battery Polyswitch 2 5 A Internal 1 Shunt consumer Polyswitch 2 5 A Internal 9 12V ON 12 12V OFF 3 5 12V indicator Polyswitch 2 5 A Internal 3 2 Negative leisure area bat sensor 11 Leisure battery sensor 8 Starter b...

Page 16: ... 1 Not assigned Not assigned Not assigned Refrigerator lines must be routed separated from further battery lines to the battery poles MNL connector sockets 5F Block 2 Leisure battery sensor Negative leisure area battery sensor Starter battery for refrigerator D input Negative starter battery for refrigerator MNL connector socket 4F Block 1 1 5 mm2 each Max 10 m compressor AES refrigerator Absorber...

Reviews: