4
– MOUNTING AND INSTALLATION
COD.
100S12/24.D.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
24
The hydraulic connections are:
Low pressure
connections
–
max 3 bar
•
Connection between seawater intake
– net
filter
– non-return valve inlet – pump group
Armorvin rinforced pipe PN6
with 20 mm internal diameter
•
Connection between the discharge of the
watermaker
– through hull discharge fittings of
the vessel
Armorvin rinforced pipe PN6
with 16 mm internal diameter
Medium pressure
connections
–
max 13 bar
•
Connections fresh water pressurized system
–
carbon filter-backflow valve outlet
–pump inlet
•
Connections pump outlet-5 microns filter
–
watermaker inlet.
Rubber rinforced pipe PN 16
minimum, internal diameter
20 mm.
Low pressure
connections -
max 3 bar
•
Watermaker - fresh water tank
¼’’ fittings, Small plastic blue
pipe 6x8mm provided within
the scope of supply
PUMP CONNECTIONS:
Connect the in/out hose to the pump as follows:
WATERMAKER INTAKE AND DISCHARGE
FIG. 4-2
CAUTION
The pump has to be placed as close as possible to the seawater intake and as low as
possible respect to the seawater level; furthermore, it is recommended to avoid long and
windy path of the connection hoses.