background image

m

 

 

General safety notes

Preserve these Operating Instructions well 

and have them carefully read by every per-

son working with the compressor. 

Important information

Attentively read these Operating Instructions. 

Most of the accidents when working with the 

compressor occur through neglect of the basic 

safety rules. Recognizing potential dangers in 

time and conscientious observance of the safety 

instructions can avoid accidents. Only use the 

compressor following the recommendations of 

the manufacturer. 

  

m

  

Safety notes

•   Do not touch moving machine parts.

•   Do not use the compressor with the guards 

 removed.

•   Always wear goggles or another adequate 

 

eye protection. Never point the compressed 

 

air current towards a part of your body or 

 

towards another person. 

•  

Protection from electric shocks.

 Avoid 

 

inadvertent contact with the cables, the 

 

tank, or earthed metal parts of the com-

 

pressor. Never use the compressor close to 

 

water or in a humid environment.

•   Pull the power supply plug before starting 

 

repair, inspection, maintenance, or cleaning 

 

work, or before replacing any parts.

•  

Inadvertent starting.

 Do not transport the 

 

compressor while it is connected to the 

 

electric power. Make sure the switch is 

 

in OFF position before you plug in the elec-

 

tric cable.

•  

Store the compressor correctly

. When 

 

the compressor is not used, it must be 

 

stored in a dry place protected from wea-

 

ther conditions.

•  

Working area.

 Make sure the work place 

 

is clean and well aerated. Put away any 

 

tools that are not needed. Do not use the 

 

compressor together with inflammable 

 

liquids or gases – risk of electric shock. 

 

Protect the compressor from rain and do 

 

not use it in humid or wet conditions. Since 

 

sparks can emanate from the compressor 

 

during work, it must be kept away from 

 

lacquers, gasoline, chemicals, glues, and 

 

other inflammable or explosive materials. 

•  

Keep children away

. Children, third per-

 

sons or animals may not get in touch with 

 

the  compressor. Unauthorized persons 

 

must  observe a safety distance from the 

 

working zone. 

•  

Working clothes

. Wear close fitting clo-

 

thes. Take off jewels as they could get 

 

caught in moving machine parts. Protect 

 

long hair by a net or cap. 

•  

Do not misuse the electric cable

. Do not 

 

remove the plug from the socket by pulling 

 

the cable. Keep the cable away from heat, 

 

oil and surfaces with sharp edges. Do not 

 

step on the cable, and do not squeeze it by 

 

putting heavy weights on it. 

•  

Carefully service the compressor

 

Regularly check the electric cable. In case 

 

of a defect, have it repaired or replaced by 

 

an authorized service station. Carefully 

 

inspect the compressor from outside and 

 

have any defects repaired by a service 

 station. 

•  

Attention.

 Keep your mind at what you are 

 

doing. Use your common sense. Never 

 

work with the compressor when you are 

 

tired, or under influence of alcohol, drugs, 

 

or medicines causing drowsiness. 

•  

Check the compressor for any defective 

 

parts or loss of ai

r. Before you use the 

 

compressor again, check the correct po-

 

sition of the moving parts, cables, mano-

 

meter, compressed air connections and 

 

all other parts important for the correct 

 

operation. Defective components must be 

 

repaired or replaced by an authorized ser-

 

vice station, observing the instructions gi-

 

ven in this manual. The compressor may 

 

not be used with the pressure control valve 

 defective.

•  

The compressor may only be used for 

 

the purposes specified in this operating 

 manual

. Do not allow children or inexperi-

 

enced persons work with the compressor. 

 

The compressor is a machine genera-

 

ting compressed air. Use it according to 

 

the instructions given in this manual. Any 

 

other use exceeds authorization. The ma-

 

nufacturer is not responsible for any dama-

 

ges resulting from unauthorized use; risk is 

 

the sole responsibility of the operator. 

•   Keep the venting grids clean, especially 

 

when working in dirty conditions.

•   Use the compressor at the rated voltage 

 

indicated on the model plate with the elec-

 

trical data. The admissible tolerance range 

 

is +/- 5 %.

•  

Never use a defective compressor

. If, 

 

during operation, you note a strange noise, 

 

excessive vibrations or any defects, switch 

 

it off immediately, check its good working 

 

order or contact your authorized service 

 station. 

•  

Only use original spare parts

. The use 

 

of non-original spare parts renders the 

 

warranty invalid, and it can cause a mal-

 

function of the compressor. Do not make 

 

any arbitrary modification on the compres-

 

sor. Have repairs done by an authorized 

 

service station. 

•   Put the switch to OFF position when the 

 

compressor is not used. Put the switch to 

 

„0“ (OFF) to interrupt the power supply. 

•   Do not touch the hot parts of the compres-

 sor.

•   Do not switch off the compressor by pulling 

 

the electric cable.

•  

Compressed air circuit

. Use compressed 

 

air hoses and tools made for a higher (or 

 

identical pressure) than the maximum ope-

 

rating pressure of the compressor.

Additional safety notes for air com-

pressors

Warning:

 Before connecting the compressor 

to the electric power (main switch on machi-

ne, socket, etc.), make sure the power supply 

corresponds with the data on the model plate. A 

higher mains voltage can cause serious injuries 

and damage the machine. Do not connect the 

machine in case of doubt. If the mains voltage is 

too low, the motor can get damaged. 

Always pull the power supply plug before 

doing any maintenance or adjustment work.

1

  Never try to remove a part from the com-

 

pressor while it is pressurized.

2

  Never try to remove an electrical part while 

 

the compressor is connected to the mains 

 

supply. Switch the machine off and pull the 

 

power supply plug.

3

  Do not adjust the safety valve.

4

  Do not use an electrical extension cable.

5

  Be careful when you vent the tank (from the 

 

safety valve, the drain plug, or the air 

 

escape). Compressed air can be extremely 

 

dangerous. Make sure the air current does 

 

not whirl up any dust, stones or other 

 

foreign bodies. Be also sure that the air 

 

does escape in a safe way.

•   In order to reduce the risk of fire or ex-

 

plosions, never spray inflammable fluids 

 

in an enclosed room. It is normal that 

 

sparks escape from the motor during 

 

operation. When these sparks get in touch 

 

with gasoline vapours or inflammable 

 

liquids, they can ignite and cause fire or 

 explosions. 

•   Always operate the compressor in a well 

 

vented room. Do not smoke during spray-

 

ing. Do not spray in the presence of sparks 

 

or flames. Keep the compressor as far as 

 

possible away from the spraying place. 

 

The liquids trichlorethane and methylen-

 

chloride can cause a chemical reaction 

 

with aluminium that is used in some paint 

 

spray cartridges and can cause an explo-

 

sion. If these liquids are used, make sure 

 

the spraying is only done with spraying bins 

 

made of stainless steel. The compressor is 

 

not impaired by these liquids. 

•   Never inhale directly the compressed air 

 

produced by the compressor. Do not use 

 

the compressed air for filling breathing 

 tanks. 

•   Do not use any welding equipment near 

 

the compressor. Do not weld anything to 

 

the air tank of the compressor: This could 

 

dangerously weaken the tank and would 

 

render the warranty invalid. 

•   Do not work with the compressor in the 

 

open air while it is raining, or on a wet base. 

 

Any of these situations could cause an 

 

electric shock. 

•   Always switch off the compressor after use 

 

and before doing any maintenance work. 

 

Press the ON/OFF button and wait until the 

 

compressed air has escaped from the tank 

 

via the drain valve. Then pull the power 

 

supply plug. 

•   Check the maximum admissible pressure of 

 

all devices used with the compressor. The 

 

output pressure on the compressor must 

 

be set in such a way that it never exceeds 

 

the prescribed pressure of devices or ac-

 cessories.

•   In order to reduce the risk of injury from 

 

moving parts, never operate the compres-

 

sor without the guard fitted. Let hot compo-

 

nents cool down before touching them. 

•   Read all labels and notes on the paint tank 

 

or on other spray materials. Carefully 

 

observe all safety instructions. Wear a 

 

breathing mask when there is a risk of inha-

 

ling spray materials. Carefully check the 

 

function of the breathing mask before put-

 

ting it on. 

•   Always wear goggles when handling the 

 

compressor. Never direct the nozzle of an 

 

accessory towards your body or towards 

 

another person.

11

D

GB

Summary of Contents for 4906113901

Page 1: ...Art Nr 4906113901 4906113850 06 2012 ac 230f D Kompressor Original Anleitung GB Compressor Translation from the original instruction manual FR Compresseur Traduction du manuel d origine...

Page 2: ...D Kompressor 5 9 GB Compressor 10 14 FR Compresseur 15 19...

Page 3: ...Fig 1 2 5 7 8 10 9 4 3 3 1 3 1...

Page 4: ...Fig 6 Fig 5 Fig 4 2 Fig 4 1 Fig 3 Fig 2 4 3 5 5 10...

Page 5: ...sparen Ausfallzeiten verringern und die Zuverl ssigkeit und Lebensdauer der Maschine erh hen Zus tzlich zu den Sicherheitsbestimmungen dieser Be die nungsanweisung m ssen Sie unbe dingt die f r den B...

Page 6: ...pressor nur f r die in dieser Gebrauchsanleitung spezifizierten Zwecke benutzen Der Kompressor ist eine Maschine die Druckluft produziert Verwenden Sie ihn gem den Anweisun gen in diesem Handbuch Lass...

Page 7: ...dem Netzanschlu und dem Ein schalten startet das Ger t automatisch Aus dem Kompressor austretende Luft darf nicht eingeatmet werden berpr fen Sie das berdruckventil t glich vor Inbetriebnahme Lassen S...

Page 8: ...der Druckschalter aktiviert und der Motor ausgeschaltet Der Druck l sst dann nach so wie die Luft durch das angeschlossene Werkzeug verbraucht wird bis der eingestellte Mini maldruck erreicht ist Dana...

Page 9: ...ffteile zu reinigen Vorsicht Wasser darf nie in Kontakt mit dem Ger t kommen Wartung des Elektrokabels Der Kabelsatz darf nur durch eine Fachwerkstatt repariert oder ausgetauscht werden Im Falle einer...

Page 10: ...h the machine safely expertly and economically and how you can avoid hazards save repair costs reduce down time and increase the reliability and service life of the machine In addition to the safety r...

Page 11: ...sor If during operation you note a strange noise excessive vibrations or any defects switch it off immediately check its good working order or contact your authorized service station Only use original...

Page 12: ...s given in the chapter Tech nical data must be adhered to The relevant accident prevention regula tions and other generally recognized safety technical rules must also be adhered to The machine may on...

Page 13: ...ssory In order to increase the air pressure turn the valve clockwise In order to reduce the air pressure turn the valve anti clockwise Attention The absence of air flow during setting produces an inco...

Page 14: ...paired if needed Foreign body in compressor Have checked by your dealer and repaired if needed Piston rod with valve seat Have the gasket enlarged by your dealer Moving parts too hot Have repaired by...

Page 15: ...es p riodes d indisponibilit comment enfin augmenter la fiabilit et la dur e de vie de la machine Outre les directives de s curit figurant dans ce manuel vous devrez observer les prescriptions r glant...

Page 16: ...uveau v rifier la position correcte des pi ces mo biles conducteurs manom tres raccorde ments d air comprim et toutes les autres pi ces essentielles pour un fonctionnement correct Les composants d fec...

Page 17: ...es sion Ne jamais essayer d enlever des pi ces de la machine tant qu elle est sous pression Porter l quipement de s curit y compris lunettes de protection ou cran protection auditive masque respiratoi...

Page 18: ...ur le manom tre r glable de la pression de sortie 3 tre r gl e par rotation du bouton r glable 4 Attention Pour pouvoir relever les valeurs correctes sur le manom tre de sortie l air doit passer par l...

Page 19: ...mag es par la chaleur en raison d une lubrification insuffisante Faire v rifier par le concessionnaire ou si n cessaire remplacer vilebrequin palier bielle de connexion segments de piston etc Pi ces m...

Page 20: ......

Page 21: ...rgmist vastavus vastavalt ELi direktiivi ja standardite j rg mist artiklinumbrit LT parei kia taip atitiktis pagal ES direktyvos ir standartai straipsn LV apliecina du saska ar ES direkt vu atbilst ba...

Page 22: ......

Page 23: ...direktiv 2002 96 EF em bortskaffelse af elektriske og elektroniske produkter og g ldende national lovgivning skal brugt elv rktoj indsamles separat og bortskaffes p en m de der sk ner milj et mest mul...

Page 24: ...t p det s ttet att vi kostnadsfritt ers tter varje maskindel som inom denna tid blir obrukbar bevisligen som f ljd av material eller tillverkningsfel F r delar som vi inte sj lva tillverkar l mnar vi...

Reviews: