www.scheppach.com
22 | GB
7.
Technical data
Filter
Connection
220-240V / 50Hz
UVC lamp power rating
11 W
Filter tank volume
9.5 l
UVC lamp holder
G23
Inlet/outlet thread
1”
Pump
Connection
220-240V / 50Hz
Power
43 W
Max. delivery flow
2500 l/h
Max. delivery height
2 m
Max. submersion depth
2 m
Protection category
IPX8
Min./max water temperature
4°C / 35°C
Length of mains connection
cable
10 m
Weight
5.5 kg
Technical changes reserved!
8. Unpacking
• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately.
Later claims will not be recognised.
• If possible, keep the packaging until the expiry of the
warranty period.
• Familiarise yourself with the product by means of the
operating instructions before using for the first time.
• With accessories as well as wearing parts and re-
placement parts use only original parts. Replace-
ment parts can be obtained from your dealer.
• When ordering please provide our article number as
well as type and year of manufacture for your equip-
ment.
m
WARNING!
The device and the packaging material are not
children‘s toys!
Do not let children play with plas-
tic bags, films or small parts!
There is a danger of
choking or suffocating!
9.
Layout
Warning!
Always pull out the mains plug before carrying out ad-
justments on the device.
1. Connect the twist-clean crank (j). (Fig.2)
2.
Fit the desired filter connection (h or i) using the
seal (g) and the union nut (f). (Fig. 2)
3. Screw the pump connection (d) onto the pump (a).
(Fig. 3)
4. Cut the hose (b) according to your needs. (Fig. 4)
5. Attach one end of the hose to the pump connection
(d) using the hose clamp (e). (Fig. 5)
6.
On the filter inlet side (7), attach the other end of
the hose to the filter connection attached previous
-
ly (h or i) using the hose clamp (e). (Fig.6)
7.
If you wish, attach the remaining hose to the filter
connection (h or u) on the filter outlet side (6) using
the hose clamp (e). (Fig. 7)
8.
Position the pressure filter (c) above the pump po
-
sition.
The hose of the filter outlet must not pro
-
trude into the water. (Fig. 8)
9. Insert the pump (a) into the water. The pump must
be positioned below the pressure filter.
(Fig. 8)
10. Start up
m
Attention!
Always make sure the device is fully assembled
before commissioning!
m
Attention!
The pump must be switched on before the filter,
otherwise the device is at risk of damage.
Switching on the device
1. Connect the mains plug of the pump. The device
starts up immediately.
2. Set the rotary switch (5) to “Run”.
3.
Connect the mains plug of the pressure filter.
Summary of Contents for 5905801917
Page 2: ...www scheppach com 2 1 1 3 4 5 6 7 8 9 2 11 12 13 14 10 ...
Page 3: ...www scheppach com 3 1a a b c d e f g h i j k ...
Page 4: ...www scheppach com 4 2 3 4 5 6 7 ...
Page 5: ...www scheppach com 5 10 8 9 11 ...
Page 37: ...www scheppach com 37 72 76 77 78 79 80 74 75 73 ...
Page 39: ...www scheppach com 39 ...