background image

14 

cable is a specification

DAMAGED ELECTRIC CONNECTING CABLES

Insulation damages frequently occur on electric connec-
ting cables. The reasons are:
•  Pressure points, if connecting cables are routed 

through window or door gaps.

•  Kinks due to improper mounting or routing of connec-

ting cables.

•  Intersections due to overruns of connecting cables.
•  Insulation damage due to pulling out from wall so-

ckets.

•  Cracks due to ageing of insulation.
Such damaged electric connecting cables should not be 
used and can be fatal because of the insulation damage

AC motor 230 V/ 50 Hz

Mains voltage 230 Volt / 50 Hz.
Mains connection and extension cable must have 3-wires 
= P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-section of 
1.5 mm².
The mains connection is secured with a max. 16A fuse.

Maintenance

Caution! Pull out power plug.

•  Clean the machine after each work cycle.
•  Replace worn out cutting discs.
•  Replace damaged protection device
•  Dust and pollution must be removed regularly from the 

machine. The best way to clean the machine is with a 
piece of cloth or brush.

•  All moveable parts must be re-lubricated at periodic 

intervals.

•  Do not use any corrosive substances to clean the plas-

tic.

•  The tub (4) and coolant pump (14) must be cleaned 

regularly to remove dirt, as otherwise the cooling of the 
diamond cutting disc (10) is not guaranteed.

Spare-part ordering

Please quote the following in your order for spare parts:
•  Type of device
•  Article No. of device
•  Ident. No. of device
•  Spare Part No. of the required spare part

Summary of Contents for FS85000

Page 1: ...Art Nr 5906703903 5906703850 05 2014 GB Tile cutting machine Translation from the original manual FS85000...

Page 2: ...lmindeligt affald I henhold til det europ iske direktiv 2012 19 EF em bortskaffelse af elektriske og elektroniske produkter og g ldende national lovgivning skal brugt elv rktoj indsamles separat og bo...

Page 3: ...GB Tile cutting machine 4 17...

Page 4: ...ntion in the tile cutting machine Risk from sudden start Caution The tile cutting machine can restart suddenly after a power failure Please read the entire text of the operating instructions thoroughl...

Page 5: ...wrench Counter torque wrench Technical data Production dimensions L x W x H 1250 x 530 x 1090 mm Cutting table 680 x 465 mm Diamond cutting disc D 180 mm Hole D 22 2 mm Water filling quantity approx 1...

Page 6: ...should not be used for application areas for which it was not designed If you are not sure please ask your dealer before working with the product Warning Non observation of these specifications can l...

Page 7: ...unction Check the alignment of moving parts breaking points installation or other such conditions that could affect the function adversely A damaged protection device or some other part must be repair...

Page 8: ...s are recommended Protect long hair with suitable means Wear eye and ear protection Always wear ANSI approved dust masks Hearing protection Always maintain your balance Do not stretch yourself over ru...

Page 9: ...Any use beyond the one specified will be treated as im proper The manufacturer will not be liable for damages resulting from such improper use the risk will be borne by the user alone m Residual risk...

Page 10: ...he voltage on the nameplate matches the existing voltage connect the power plug to the mains power supply only thereafter The cutting disc should be free to run before the ma chine is switched on Caut...

Page 11: ...rails 9 Cutting disc protection 10 Diamond cutting disc 11 Handle 12 Star knob screw for angle adjustment 13 Pin for transport lock 14 Cooling water pump 15 Hose 16 Motor 17 ON OFF switch 18 Angle sca...

Page 12: ...ss the I of the On Off switch 17 Before starting the cutting operation you must wait for the cutting disc to reach its max speed and for the coo ling water pump 14 to pump water to the cutting disc To...

Page 13: ...lange 23 and cutting disc 10 Fig 11 5 Clean the supporting flange carefully before installing the new cutting disc 6 Insert the cutting disc in the reverse sequence and tighten it Caution Pay attentio...

Page 14: ...P N SL 1 N PE Extension cables must have a minimum cross section of 1 5 mm The mains connection is secured with a max 16A fuse Maintenance Caution Pull out power plug Clean the machine after each wor...

Page 15: ...duct carefully Impacts hits and drops from even low heights can damage the machine Never use the product if it is brought from a cold to a hot room Under certain circumstances the resulting condensed...

Page 16: ...nect the load from the mains This is dis played in the window through the disappearance of the red symbol Protection of man and animal is effective only if the machine works properly The Reset button...

Page 17: ...mains circuit breaker a Check mains circuit breaker b Extension cable defective b Replace extension cable c Connection with motor or switch is not OK c Have it checked by an electrician d Motor or sw...

Page 18: ...63 62 61 60 59 58 57 55 54 53 52 51 50 49 48 47 46 70 45 44 43 42 41 39 40 38 37 36 33 26 25 24 21 72 71 70 73 74 69 3 2 1 56 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 18 20 32 34 35 68 81 82 80 83 22 23...

Page 19: ...a du saska ar ES direkt vu atbilst bas un standarti du rakstu NL verklaart hierbij dat het volgende artikel voldoet aan de daarop betrekking hebbende EG richtlijnen en normen RUS PT declara o seguinte...

Page 20: ......

Reviews: