www.scheppach.com /
service@scheppach.com /
+(49)-08223-4002-99 /
+(49)-08223-4002-58
26 | GB
• Afterwards, close the oil drain plug again.
•
Remove the ventilation cap, pour in 9 litres of fresh
hydraulic oil using a clean funnel.
•
Replace the ventilation cap (12).
Warning! Ensure that no debris gets into the oil
container.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
We recommend oil from the HLP 32 range.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is deliv
-
ered, and may not be changed or manipulated.
Connections and repairs
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
•
Type of current for the motor
•
Machine data - type plate
•
Machine data - type plate
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: hydraulic oil, splitting wedge, Transmis
-
sion oil
* Not necessarily included in the scope of delivery!
16. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip
-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.
When connecting to the mains or relocating the ma
-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.
12. Cleaning
Attention!
Pull out the power plug before carrying out any clean
-
ing work on the equipment.
We recommend that you clean the equipment imme
-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
13. Transport
Before transporting the kindling splitter, ensure it is
in the transport position. To do this, lower the riving
knife until it rests on the metal support. Next, remove
both shafts and allow the cylinder to move down
-
wards finally. You can set the splitter onto a palette
with the help of a crane, but never lift the splitter by
the splitting blade. The top part of the splitter features
an eyelet, where the crane hook may be engaged.
14.
Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
15. Maintenance
Attention!
Pull out the power plug before carrying out any main
-
tenance work on the equipment. Make sure that the
drive shaft is not connected to the traction unit.
When must the oil be changed?
First oil change after 50 operating hours, then every
250 operating hours.
Replacing the oil (fig. 9 + 10)
•
Completely retract the splitting knife.
• Put a container with a volume of at least 10 litres
under the splitter.
•
Loosen the ventilation cap (12).
• Open the oil drain plug under the oil tank so the oil
can flow out.
Summary of Contents for HL1300
Page 2: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 2...
Page 6: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 13 2 3 16 15 9 B A...
Page 141: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 141...
Page 142: ...www scheppach com service scheppach com 49 08223 4002 99 49 08223 4002 58 142...