2
Index page
1. Safety information...............................
Caution!
2. Range of applications..........................
3. List of contents....................................
4. Accessories/options..............................
5. Initial start-up and installation
switching on and off............................
6. Tool change on motorhandpiece..........
7. Operation of the controls.....................
8. Control satellite...................................
9. Basis and additional functions.............
10. Menu structure and basic settings.......
11. Speed control functions.......................
12. Cleaning and Maintenance/.................
removing the chuck
13. Possible error messages.......................
Reset after error message
14. Suggestions for wax knife...................
15. Technical Data.....................................
16. Declaration of conformity....................
1. Safety information
- When using rotary instruments, do not
exceed the maximum speeds laid down by
their manufacturer.
- When operation with left-hand rotation, the
collet may loosen when there is a high load.
- Repairs and other technical procedures must
only be carried out by suitable qualified
personnel, authorized by SCHICK.
- SCHICK do not guarantee the
unit
should it not have been used in accordance
with the instructions.
1.1 Ascertain that your mains supply coincides
with the data on the rating plate.
1.2
- units are not suitable for the
following applications:
- in areas where there is a risk of explosion
- for medical applications
- for working on moist materials
1.3 Ensure that all regulatory requirements are
observed during use
- always wear protective glasses
- provide enough light at the working place
- use dust suction
1.4 Under no circumstances should the
motor handpiece be cleaned with
compressed air.
1.5 Before putting the handpiece down, always
insert a rotary instrument or the pin, supplied
with the unit, into chuck.
Caution:
2. Range of applications
The
unit is designed for universal use in
dental laboratories when trimming crowns and
bridges, respectively acrylic and light chrome cobalt
dentures. With its speed range from
200 - 50.000 rpm the SCHICK
- unit allows
to work all dental materials.
The complete new technology of
enables
changing the tools without changing the grip
position of the hands.
The kernel of the technology is the pneumatical chuck
system which replaces the normal collet chuck
technology.
Conditions of environment:
- interior 5° - 40° C.
- up to 2,000 meter over sea level
Categorie of overvoltage: II
Grade of pollution: 2
WEEE-Reg.-Nr. DE 78620387
We are pleased that you decided
to buy a highly developed piece of
equipment from SCHICK and
would like to wish you every
success when working with your
new
control unit.
We wrote these instructions to
enable you to get accustomed to
your new piece of equipment
and to provide you with the
correct operating and
maintenance instructions.