background image

 

2.2  Tools and Materials 

To install the sensor and codestrip, you will need the following tools and materials. 

A.

 

Allen key to remove patient alignment adjustment knob and tighten replacement knob 
in position. 

B.

 

Allen key (3/32 in.) to adjust clearance between encoder and codestrip. 

C.

 

Phillips screwdriver to install sensor clip. 

D.

 

Screwdriver to remove bar from drum velcro area.  

E.

 

Fine-point marker or pencil to draw guideline for codestrip. 

 

 

 

B1051109 Rev. – (Draft 2) 

Panelipse Installation

 

Summary of Contents for CDRPan

Page 1: ...ate __________ Joseph Tetro Technical Writer Approved by _______________________________ Date __________ Scott Doyle Project Manager Approved by _______________________________ Date __________ John Goyette Director of Software Development Approved by _______________________________ Date __________ Enrico Renzi Director of Quality Assurance Approved by _______________________________ Date _________...

Page 2: ......

Page 3: ...Revision History Rev Description of Change Date Approved Initial Release shewing files to convert FAQ 7174 Pano_Install_GEPanelipse doc ...

Page 4: ...NORAMIC SYSTEMS Installation Instructions for GE Panelipse Gendex Panelipse II Schick Technologies Inc 31 00 47th Avenue Long Island City New York 11101 718 937 5765 718 937 5962 FAX Part Number B1051109 Rev Draft 2 ...

Page 5: ...eir products are claimed as trademarks Where those designations appear in this document and Schick Technologies Inc was aware of a trademark claim the designations have been printed in caps or initial caps Part Number B1051109 Rev Draft 2 June 22 2000 Printed in the United States of America This document was originally prepared in English ...

Page 6: ......

Page 7: ...or Assembly and Sensor Clip 10 3 4 Route Sensor Cable 12 3 5 Check Sensor Cable Run 14 3 6 Prepare to Install Codestrip 15 3 7 Install Codestrip 16 3 8 Clearance Adjustments 17 4 Remote Module Power Supply and PCI Board 18 4 1 Install Remote Module 18 4 1 1 Tools and Materials 18 4 1 2 Step by Step Instructions 18 4 2 Install Power Supply 19 4 2 1 Tools and Materials 19 4 2 2 Step by Step Instruct...

Page 8: ...an be found in the CDRPan User s Guide Mechanical Considerations The sensor package the remote module and the cables of the CDRPan system are mounted outside of the patient area to ensure patient safety and reliable equipment operation Radiation Concerns No adjustments or alterations are made to the X ray source of the panoramic equipment B1051109 Rev Draft 2 Panelipse Installation ii ...

Page 9: ...100 and cable B2211001 The CDRPan system requires the following software CDR software version 2 1 or higher CDRPan software which includes the PCI board device driver and the series set to be used with panoramic exams 1 3 Overview for Installing CDRPan This Installation Manual is one of two documents you will need to install the CDRPan system completely After performing the installation procedures...

Page 10: ...amiliarize yourself with the installation steps before performing them Determine the location of your computer This will be useful when you install the Remote Module and need to run cables between it and your computer X RAY SOURCE FACEPLATE DRUM ROTATION ARM PICTURE TO BE SUPPLIED Figure 1 Picture of the GE Panelipse Gendex Panelipse II B1051109 Rev Draft 2 Panelipse Installation 2 ...

Page 11: ...on 2 1 CDRPan System To perform the installation procedures in this manual you will need the following CDRPan parts and assemblies A Sensor Assembly B Drum Codestrip Not Shown C Remote Module Panelipse Installation B1051109 Rev Draft 2 3 ...

Page 12: ...D Cable Holders and Clamps E Power Supply F PCI Board B1051109 Rev Draft 2 Panelipse Installation 4 ...

Page 13: ...G Data Cable for PCI Board H Patient Alignment Adjustment Knob I X ray Filter and Allen Key Panelipse Installation B1051109 Rev Draft 2 5 ...

Page 14: ...alignment adjustment knob and tighten replacement knob in position B Allen key 3 32 in to adjust clearance between encoder and codestrip C Phillips screwdriver to install sensor clip D Screwdriver to remove bar from drum velcro area E Fine point marker or pencil to draw guideline for codestrip B1051109 Rev Draft 2 Panelipse Installation 6 ...

Page 15: ... Adjustment Knob A Locate the patient alignment adjustment knob near the chin rest area Using allen wrench loosen and then remove the knob ADJUSTMENT KNOB PICTURE TO BE SUPPLIED PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 7 ...

Page 16: ...ecure it in position with the allen wrench This replacement knob has a smaller diameter to ensure that the drum can travel without interference once the sensor assembly is installed NEW ADJUSTMENT KNOB PICTURE TO BE SUPPLIED B1051109 Rev Draft 2 Panelipse Installation 8 ...

Page 17: ...3 2 Remove Bar from Velcro Area Remove the vertical aluminum bar located at the center of the drum velcro area PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 9 ...

Page 18: ...ly into the aperture until the upper guide is seated firmly at the top of the aperture slit and the lower guide fits in the bottom of the aperture C Install the sensor clip at the bottom of the faceplate UPPER GUIDE LOWER GUIDE SENSOR CLIP PICTURE TO BE SUPPLIED PICTURE TO BE SUPPLIED B1051109 Rev Draft 2 Panelipse Installation 10 ...

Page 19: ...ify that the sensor assembly is located correctly with the motion encoder facing towards the drum Secure the clip in place using a Phillips screwdriver to tighten 2 screws PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 11 ...

Page 20: ... A Use cable clamp to secure sensor cable inside the faceplate Continue attaching clamps and holders to feed cable along contours of the panoramic machine PICTURE TO BE SUPPLIED B1051109 Rev Draft 2 Panelipse Installation 12 ...

Page 21: ...B Route cable to the top of the panoramic machine following the edge nearest the control panel PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 13 ...

Page 22: ...e Run Swivel the arm of the panoramic machine to ensure there is enough slack in the cable for the rotation arm to move freely Adjust cable if necessary PICTURE TO BE SUPPLIED B1051109 Rev Draft 2 Panelipse Installation 14 ...

Page 23: ... faceplate and then mark that spot using a fine point marker or pen B Rotate the drum marking a straight line around it This line will be used for aligning and mounting the codestrip PICTURE TO BE SUPPLIED PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 15 ...

Page 24: ...mounting tape and apply the codestrip with adhesive side towards drum Ensure there are NO kinks or bubbles when the codestrip is applied Installing the codestrip unevenly or without optimal contact with the faceplate may cause motion artifacts in images PICTURE TO BE SUPPLIED B1051109 Rev Draft 2 Panelipse Installation 16 ...

Page 25: ...e to verify that the bottom of the sensor assembly clears all of the patient alignment supports B Also verify that the sensor cable does not kink bind or pull out of clips when the rotating arm is in motion CHECK FOR CLEARANCE PICTURE TO BE SUPPLIED Panelipse Installation B1051009 Rev Draft 2 17 ...

Page 26: ...mote module 4 1 2 Step by Step Instructions A Apply velcro to the top of the panoramic machine along the top edge of the rotational arm This will make it easy to see the status lights on the module B Apply velcro to the bottom of the remote module also and mount the remote module to the panoramic machine C Connect the sensor cable to the remote module Then use a small screwdriver to tighten the sc...

Page 27: ...upply you will need cable holders and clamps P N B4700140 to secure the cable along the side of the panoramic machine and up to the remote module 4 2 2 Step by Step Instructions A Position power supply at base of panoramic machine B Route connector cable to the remote module at the top of the panoramic machine C Connect the connector cable to the remote module D Plug the power supply cable into a ...

Page 28: ...d to the PCI board 4 3 2 Step by Step Instructions A Ensure the computer is turned off and not plugged into an outlet B Follow the instructions supplied with your computer to remove the cover Locate an empty PCI slot in the motherboard and install the PCI board C Replace the computer cover D Connect either end of the data cable to the PCI board Then use a small screwdriver to tighten the screws on...

Page 29: ...v Draft 2 21 F Refer to the CDRPan User s Guide P N B1051008 to continue with CDRPan system installation E Connect the other end of the data cable to the remote module Then use a small secrewdriver to tighten the screws on the connector ...

Page 30: ......

Page 31: ...ct power cord to wall outlet ª Connect cable from CDR Pan PCI board at back of Computer to Remote Module c Computer Printer Drum Type Film Holder Cable Mounting Clip Sensor Package Remote Module Power Supply PLEASE NOTE Before applying the velcro patches clean the surface of the panoramic machine ensure good adhesion PLEASE NOTE Before applying the velcro patches clean the surface of the panoramic...

Page 32: ...Panelipse Installation B1051109 Rev Draft 2 24 ...

Page 33: ...Panelipse Installation B1051109 Rev Draft 2 25 ...

Reviews: