Sirius Operating Manual
Sirius Operating Manual
Page |
20
Device set to “0”
(only permitted in areas not covered by DEFRA restrictions for use on wood burning
appliances).
When set to “0“, the air feed is closed, and no combustion air is supplied = this should be
the setting if the device is not going to be used for long periods (e.g. in summer).
Heat setting “1“
When set to “1“, primary and secondary air is supplied in a ratio optimal for a clean
combustion process = setting to operate the device at nominal capacity.
Heat setting “2“
A large amount of combustion air is needed in the igniting phase and the lever should be
pushed all the way to the right to setting “2” = maximum supply of primary and secondary
air.
PLEASE NOTE Setting “2” should only be selected for igniting purposes!
Dampers left open
Operation with the air control or appliance dampers open can cause excess smoke. The
appliance must not be operated with air controls, appliance dampers or door left open
except as directed in the instructions.
In order for the stove to comply with the DEFRA exempt conditions, a DEFRA kit
must be installed, as per the instructions below: