LOCKING DEVICE
CONNECTING THE CABLE REEL
EXTENSION CABLE
THERMAL SAFETY GUARDS
In order to avoid an overheating of the cable reel, depending of the product version
varying safety methods are used.
• The maximum payload is reduced by a 10A special glass bulb fuse. In the single-
phase version, the phase is fused. On the three-phase versions all three phases
are fused. The glass tube fuse is seated in the terminal block.
• The nominal current can be reduced by a fuse within the distribution box.
The included standard cables are designed to tolerate the weight of the pulled-out cable including the cable stopper. Additional
weights are not allowed. The mounted cables are limited to the specified lengths. Never use excessive force to unwind the cable as
this can damage both the cable and the reel. Should the cable be blocked while coiling up, please pull the cable out again and recoil.
Attention should also be paid to section „GENERAL" and “CONTINOUS OPERATION".
In the case of versions without pull-out cables, the cable is connected as described under "EXCHANGING THE PULL-OUT CABLE”.
As a standard feature the cable reel has a cable locking device. The latching
mechanism ensures that the pulled-out cable stays without traction fixed in
place. When the cable is being pulled out, the spring detent passes over a
series of grooves. An audible click indicates that the locking device is
engaged. If you gently rewind the cable after the clicking sound, you will
notice that the spring detent will engage into the notches, locking the cable
in position. The cable can be disengaged by gently continuing to pull the
cable until the click can no longer be heard. The tensioned spring will pull
the cable back onto the reel.
The locking device
FT 150
can be disengaged by releasing the screw on the
lock. Pull out the catch approx. 1cm and screw it on again by 180°. This will
disengage the locking device the cable is then constantly under tension.
ATTENTION
Do not release the cable when rewinding, the tension of the spring can accelerate the winding speed to such a degree
that the swinging able end could cause injury. Also damage to the cable and spring could be the result of such an action.
The cable reels are unless otherwise agreed supplied without connection
cable. The connection cable can be mounted in a individual length to the
internal fuse terminal according to the sketch above.
ATTENTION
Make sure the yellow / green earth wire is connected to the fuse
terminal marked with the grounding mark and the strain
relief is tightened.
LOAD
Please refer to the details on the product label or if the cable is fitted by yourself, please adhere to the details supplied by
DIN EN 50565-1 regarding the performance of the used cable.