automatic hose rewinder ST 260/350 and EST 265
installation and operating instruction
installation and operating instruction ST 260_350-EST 265 - A5
page 4
01.04.2021
Schill GmbH & Co. KG; Bruckstraße 44; 70734 Fellbach
TECHNICAL DATA
Our hose reels with their robust design are made for operating in factories and workshops. The sturdy plastic design, made from high-quality
materials, corrosion resistant and has very good winding characteristics. The cable reels come as a standard without connection hose.
•
Spiral spring for approx. 30,000 operations
•
Cable locking device (disengageable only ST 260/350 versions) with spring detent
•
Wear- and corrosion-free brass axis
•
Swivel joint made of MS58 with 6mm bore.
•
Seal with Perbunan O-rings
•
Rubber hose NW 6 fabric-reinforced
•
Hose fitting with 6-KT nut.
•
Hose stopper with lamella clamping:6 - 12mm ST 260 and EST 265 / 6 - 16mm ST 350
•
Universal holder for wall or ceiling mounting ST 260/350
•
Ambient temperature range 5°C to 35°C
•
side connection: screw-on R 1/4" outside
Additional information with respect to hose types, spring tensions, power loads and weights can be found on the product rating plate, in our
current product catalogue and on our website
EXCHANGING THE PULL-OUT HOSE
•
Disconnect the hose reel from the power supply and remove from the operation site.
•
Roll off the hose a little and lock the drum against a roll-up via the locking.
ATTENTION
The spiral spring in the coil is under tension. Please ensure that the locking mechanism is activated.
•
Remove the brass nut on the connection fitting.
•
Loosen all the screws and remove the housing cover.
•
To replace the pull-out hose, you should make sure the spring is unwound for your own safety! Please adhere to the following
instruction:
1.
Carefully pull on the hose stopper until the click of the notches have faded, you immediately notice a pull on the hose
stopper in the opposite direction.
2.
Let the coil run back slowly and count the number of turns. This is important to adjust later the exact preload on the spring
again, without damage to coil or spiral spring. In the end the coil should be able to move freely.
3.
Remove completely the damaged hose from the coil.
4.
Disconnect the hose from the swivel joint connection.
5.
Remove strain relief inside the coil.
6.
Remove defective pull-out hose.
7.
Remove the hose stopper from the defective cable and attach to the new cable.
•
Undertake the re-assembly in reverse order
(see “TIGHTENING TORQUE”).
•
Adjust the pre-load:
Hold the hose stopper outside the housing and hold it with one hand. Now turn the coil as often as you counted. At the end let it
snap into the notches (see "LOCKING DEVICE").
•
After the complete re-assembly undo the locking. Pull on the hose stopper, wind out the cable complete and slowly rewind it.
•
Before re-mounting at the
operation area, please check for a correct performance. (see “READY TO USE”).
EXCHANGING THE SPIRAL SPRING
•
Disconnect the hose reel from the power supply and remove from the operation site.
•
Roll off the hose a little and lock the drum against a roll-up via the locking.
ATTENTION
The spiral spring in the coil is under tension. Please ensure that the locking mechanism is activated.
•
Remove the brass nut on the connection fitting.
•
Loosen all the screws and remove the housing cover.
•
To replace the pull-out hose, you should make sure the spring is unwound for your own safety! Please adhere to the following
instruction:
1.
Carefully pull on the hose stopper until the click of the notches have faded, you immediately notice a pull on the hose
stopper in the opposite direction.