automatic hose rewinder ST 260/350 and EST 265
installation and operating instruction
installation and operating instruction ST 260_350-EST 265 - A5
page 5
01.04.2021
Schill GmbH & Co. KG; Bruckstraße 44; 70734 Fellbach
2.
Let the coil run back slowly and count the number of turns. This is important to adjust later the exact preload on the spring
again, without damage to coil or spiral spring. In the end the coil should be able to move freely.
•
Turn the drum and release the coil from the housing by undoing the centre screw.
•
Put the coil on the side with the spring cover disc top. Remove the spring cover disk.
•
Remove the screws of the spring cover and the spring cover.
•
Carefully remove defective spring.
ATTENTION
Due to the manufacturing design the spring is under tension and could unwind very fast and cause injuries if handled
improper.
•
Carefully Re-assemble the coil. Undertake the Re-assembly in reverse order
(see “TIGHTENING TORQUE”).
•
If necessary, wind down the pull-out cable completely by turning the coil and insert the new spring.
Pay attention to the installation
position!
•
Insert the new spring.
Pay attention to the installation position!
•
Assemble the spring cover disc. Ensure the retainer pin is engaging the spring eye.
•
Adjust the pre-load:
Hold the stopper outside the housing and hold it with one hand. Now turn the coil as often as you counted. At the end let it snap into
the notches (see "LOCKING DEVICE").
•
After the complete re-assembly undo the locking. Pull on the cable stopper, wind out the hose complete and slowly rewind it.
•
Before re-
mounting at the operation area, please check for a correct performance (see “Ready to use”).
INSTALLATION HEIGHT
The installation height of the cable rewinder is not limited. The maximum extension length is the specified cable length. The standard cables
are designed to withstand the weight of the extended cable included cable stopper. Additional tensile forces (cause by additional weights for
example) are not permitted.
When the cable is pull-out horizontally due to the weight of cable a slack occurs. This is about 10% of the cable pull-out length.
FITTING INSTRUCTIONS ST 260
Wall mounting with universal holder DWB260
The cable reel can be rotated 150°.
PLEASE NOTE
The cable reel housing must be pushed onto the universal holder
pin, then insert the slider into the intended position of the cable
reel housing.