SIGNALING ELEMENTS
FT 038.XXXX.I1X
Tint
Description
OFF
Missing power supply
or micro fuse defective
or missing release (see release contact)
White permanent
Operational
GREEN permanent
Vehicle detected
BLUE permanent
Charge active
BLUE flashing
2 sec ON / 2 sec OFF
Request cooling
GREEN/WHITE flashing
1 sec green / 1 sec white
DIP switch set incorrectly
GREEN/WHITE flashing
1,5 sec green / 0,5 sec white
Undefined voltage read in at the CP contact
GREEN flashing
1 sec green / 1 sec OFF
System error (please contact the manufacturer)