PROTECTIVE DEVICES
Fuse:
The integrated charging electronic is fused with a 5x20 glass bulb fuse. This is located on
the charge controller (see also "CHARGE CONTROLLER") in the core of the reel. To
change the fuse, unscrew the cover from the reel. The glass bulb fuse on the charge
controller can then be replaced.
Temperature protection:
The series of these automatic cable reels with integrated charging electronics is
dimensioned in such a way that no excessive heat is generated when the cable is reeled
or unreeled. For protection in case of unusual heat development, a self-holding or self-
switching temperature switch is installed, depending on the version. In the event of
tripping, the charging of the electrically powered vehicle is interrupted. After a cooling
phase, the temperature switch switches itself on or is reactivated by pressing the red
temperature switch. Charging operation is resumed (see also "SIGNALING ELEMENTS").
Residual current protection
The DC guard integrated in the rewinder has a test button for
checking the residual current protection. By pressing, a 6 mA DC
residual current is generated. Then, the DC guard generates an AC
residual current which triggers the residual current circuit breaker in
the house distribution.
This functionality must be checked during the commissioning of the
device and later once a year.