Automatic cable rewinder FT / FTE 350
Fitting and operating instructions
Bedienungsanleitung_FT 350
Seite 16
10.03.2020
Schill GmbH & Co.KG, Bruckstrasse 44, 70734 Fellbach
CABLE TERMINAL
The cable reels are unless
otherwise agreed supplied without
connection cable.
The connection cable can be
connected in individual length to
the existing fuse terminal
according to the sketch opposite.
Make sure the yellow / green earth wire is connected to the fuse terminal
marked with the grounding mark and the strain relief is tightened.
EXTENSION CABLE
The included standard cables are designed to tolerate the weight of the pulled-out
cable including the cable stopper. Additional weights are not allowed. The mounted
cables are limited to the specified lengths. Never use excessive force to unwind the
cable as this can damage both the cable and the reel. Should the cable be blocked
while coiling up, please pull the cable out again and recoil. Attention should also be
paid to section „GENERAL" and “CONTINOUS OPERATION".
In the case of versions without pull-out cables, the cable is connected as described
under " EXCHANGING THE PULL-OUT CABLE
"
THERMAL SAFETY GUARDS
In order to avoid an overheating of the cable reel, depending of the product version
varying safety methods are used.
•
The maximum payload is reduced by a 10 A special glass bulb fuse. In the
single-phase version, the phase is fused. On the three-phase versions all
three phases are fused. The glass tube fuse is seated in the terminal block.
•
If the use of 16 A is relevant a self-retaining thermal switch for the single-
phase versions can be implemented. If activated the power supply will be cut
out. The power supply can be re-started by pressing the button after a cool
down time.
•
the nominal current can be reduced by a 10A fuse within the distribution box.