When operating the actuating drive, a distinction is made between two different
operating states:
Standard mode
and
Configuration mode
.
In
Standard mode
, the drive is controlled depending on the settings activated based
on the input signals applied.
In
Configuration mode
, changes are applied to settings, such as changing the
rotation speed or the calibration for the analogue signals.
Description of operating elements
Rotary
switch S10
“Mode”
When set to mode “0”, the drive is in normal operation.
In this mode, the desired operating mode can be selected using the
Parameter rotary switch. As soon as a mode other than “0” is selected,
the drive will be in configuration mode.
Rotary
switch S11
“Parameter
”
In standard mode, the desired operating mode is selected using the
Parameter rotary switch.
In configuration mode, the desired value is selected using the Parameter
rotary switch.
Button S12
“PROG”
In configuration mode, settings are confirmed by pressing and holding
this button.
Button S13
In the “manual movement” and “manual movement, ignore limit switch”
operating modes, a counterclockwise (CCW) rotation of the drive is
started
. If the button is released or the end position is reached
(operating mode “manual movement” only), the rotary movement stops.
In configuration mode, the button may perform special functions.
Button S14
In the “manual movement” and “manual movement, ignore limit switch”
operating modes, a clockwise (CW) rotation of the drive is started
. If