Schindler 3100/3300/6300
J 43402603 / 01
130/269
Copyright © 2017 INVENTIO AG
*) So marked error descriptions are not released officially by R&D. If necessary, contact
a specialist or the Locarno hotline for more information.
*) So marked error descriptions are not released officially by R&D. If necessary, contact
a specialist or the Locarno hotline for more information.
1589
FC MISSING SAFETY CHAIN SUPPLY
During or while starting a trip (while the motor and brake contactors are
activated) the drive has detected a interrupted safety circuit
C1:Safety circuit signal is faulty
A1:Check safety circuit wiring between elevator control and drive
C2:The trip was started before the door has finished bouncing after
reaching the closed position
A2:Increase parameter start delay (menu CF 03)
C3:JEM on PEBO (SNGL, SEM3x) is on wrong position
A3:Switch JEM to position OFF
1593
FC NON DETERMINABLE PERS AT STARTUP
The persistent error from FC has been lost due to startup sequence
1594
FC HW ERROR
HW failure of the converter detected
1595
FC HW MISMATCH
The configuration does not match with recognized hardware
1596
FC SW WARNING
The software detected an exceptional behavior of the SW or the HW
1597
FC MEMORY ERROR
Incorrect memory access
1598
FC PARAMETER INCONSISTENCY
Parameter values out of range.
1599
FC INVERTER INTERNAL FAILURE
The drive inverter has an internal problem. See extra info for more information
drive internal error code. See corresponding drive manual
Code
SEM3x Message
1601
SEM3x GENERAL ERROR *)
Code
SIM/Chip Card Message
1901
CHIP CARD WRONG DEVICE
The elevator main controller has a software internal problem accessing the
SIM card
C1:Internal elevator main controller software error
A1:Upgrade elevator main controller software (SCIC)
Code
Frequency Converter Error Message