SHAFT INCONSISTENT KSE D U STATE
The signal indicating the hoistway end is invalid (for example, inconsistent).
Failure at hoistway information.
C1:A hoistway end position indicator (for example, KSE, KSE_U, KSE_D)
is missing or not at the correct position.
A1:Check correct position of the corresponding indicator (for example,
magnet and its polarity, vane)
C2:A hoistway end position sensor is faulty.
A2:Check functionality of corresponding sensor. Replace it if necessary.
C3:Wiring to hoistway end position sensor is faulty.
A3:Check wiring at the corresponding sensor.
2133
SHAFT MIX KSE AND KSE D U
The elevator control received signals from the hoistway information system
which aren't signals of the expected hoistway information system type.
C1:Wiring to hoistway end position sensor is faulty.
A1:Check wiring and correct connection of the corresponding sensor
(KSE, KSE_U, KSE_D).
2134
SHAFT KSE AND TSD OPTION
2135
SHAFT TSD SIGNAL CHANGE
The elevator has detected an unexpected change of the signal TSD (state of
the presence of the temporary safety device).
C1:The wiring at the signal TSD is faulty
A1:Check general wiring
C2:The elevator main controller board was exchanged by a board from
another elevator
A2:Perform the learning travel. At no success replace elevator main
controller board (for example, SCIC, SCPU) by a new one from the
factory.
2136
SHAFT ROUGH POS MISSMATCH TOP
Failure at the upper hoistway end detection
C1:Wiring to the upper hoistway end position sensor is faulty.
A1:Check wiring at the corresponding sensor.
C2:The upper hoistway end position sensor is faulty.
A2:Check functionality of corresponding sensor. Replace it if necessary.
Code