Schindler 3100/3300/6300
J 43402603 / 01
161/269
Copyright © 2017 INVENTIO AG
4612
TM RES STRENGTH MONITORING DATA MISMATCH
Data mismatch between master and backup storages of traction media
insufficient strength monitoring. The reference keys of both storages are
identical. The highest STM trip count value and the lowest STM trip count limit
are replicated to both storages.
C1:The controller found different STM bending counter in the redundant
storages.
A1:None
C2:The controller found different STM bending limits in the redundant
storages. The new value is taken from chip card.
A2:None
C3:The controller found different STM bending warning levels in the
redundant storages. The new value is taken from chip card.
A3:None
C4:The controller found different SBPT in the redundant storages. The
new value is taken from chip card.
A4:None
4613
TM RES STRENGTH MONITORING BACKUP MISSING
Missing backup storage of traction media insufficient strength monitoring.
C1: STM data cannot be saved on chip card
A1:Replace chip card with one with 1k
4615
TM DATA MEMORY RECOVERY SUCCESS
Successful recovery of traction media data storage memory
C1:A mismatch in STM data has been found and solved.
A1:Check previous log entries to see the reason of mismatch.
4616
TM DATA MEMORY RECOVERY UNSUCCESSFUL
Recovery of traction media data storage memory was not successful. The
reference key did not match any of the storages or restore failed.
C1:Reference key entered is wrong.
A1:Enter the correct reference key for the elevator from the maintenance
log.
C2:Fault of one or both storage devices.
A2:Replace the faulty storage device. See previous log entry for detail.
C3:Both storage devices are from a different elevator or virgin.
A3:Re-enter the STM installation data from the maintenance log.
C4:STM chip card option is missing
A4:Replace chip card with one with STM option enabled
4617
TM INSTALLATION DATA ENTERED
Traction media installation data had been entered successfully.
C1:The procedure of configuring the STM parameter is terminated
A1:Reset the controller
4618
TM STRESS COUNT ENTERED
The STM stress count (trip or tend cycle counter) was set.
C1:A new STM bending counter has been entered. The advanced STM
configuration has been used.
A1:None
Code
Overlay Message