Schindler 3100/3300/6300
J 43402603 / 01
162/269
Copyright © 2017 INVENTIO AG
4619
TM AGING CLOCK RECOVERY SUCCESS
The failure of the internal clock had been recovered.
C1:The maintenance person set the clock
A1:None
4620
TM AGING CLOCK RECOVERY FAILED
The failure of the internal clock had not been recovered within the permitted
time.
C1:The internal clock had been stopped due to a loss of mains and
battery power.
A1:Set date and time.
C2:The controller expects soon an STM expiration
A2:Set date and time.
C3:The controller uses all the 210 days granted to set the correct date
and time
A3:Set date and time.
4621
TM RETAINER FAILURE
The failure of the belt retainer has been detected. Only recall, installation and
inspection movements are allowed
C1:The belt retainer has reported a problem
A1:Inspect belt, inspect retainer.
4622
TM RETAINER RECOVERY SUCCESS
The belt retainer has encouraged from an error
4623
TM ECM ERROR
The STM conductivity test has failed
C1:Ground failure on the belt
A1:Inspect the belts
4624
TM_ECM _WARNING
The conductivity test is out of range.
4625
TM ECM UNAVAILABLE
The conductivity device for STM:- Is no more alive (heartbeat lost)- Reports
self check failure- Reports calibration error
C1:ECM calibration failure
A1:None
C2:ECM heartbeat is lost
A2:Check communication cable
C3:ECM reports a self test failure
A3:Replace hardware
4626
TM ECM AVAILABLE
The conductivity device for STM is back in normal monitoring operation.