TM RES AGING MONITORING DATA MISMATCH
Data mismatch between master and backup storages of traction media aging
monitoring. The reference keys of both storage are identical. The aging limit
and the aging warning limit differs on both storages.
C1:Manufacturing date differs
A1:Activate menu 190 and enter the correct belt manufacturing date.
C2:Aging limit differs
A2:Clear the fatal error
C3:Aging warning limit differs
A3:Clear the fatal error
4630
TM BENDING STRESS COUNT ENTERED
Traction media bending stress counter entered
C1:There is a problem with the cabling.
A1:Check the proper cabling of the overlay box.
4631
TM BENDING STRESS COUNTER MISMATCH
This error is generated when there is a mismatch between bending counter in
EEPROM and on SIM card.
4632
TM MANUFACTURING DATE MISMATCH
This error is generated when there is a mismatch between manufacturing date
in EEPROM and on sim card
4701
OVERLAY HEARTBEAT MISSING
The heartbeat from the overlay is missing.
The main controller did loose for some time the connection to the overlay
board.
In case this error is detected the bionic controller gets out of the group and
continues to serve all calls in a simplex fashion.
If the connection to the overlay is recovered the information OVERLAY
HEARTBEAT RECOVERED is recorded in the log as well.
C1:There is a problem with the cabling.
A1:Check the proper cabling of the overlay box.
C2:The overlay board has a problem
A2:
C3:The overlay did perform a reset
A3:
4703
OVERLAY HEARTBEAT RECOVERED
The elevator control starts to receive the heartbeat from the overlay.
C1:This information is stored in the log of events if a previously lost
connection to the overlay board is now recovered.
A1:none
4705
OVERLAY ELEVATOR IN GROUP MISSING
Overlay component are missing in the group.
C1:This error is inserted in the log if one or more controllers are no
longer part of the group. It is possible that the error is detected only by
some elevators of the group.
A1:To better understand what causes the issue it is advised to check the
overlay monitoring menu (HMI menu 30 > 309) as the values there can be
a certain help in pinpointing where the group problem might be.