Schindler 3100/3300/6300
J 43402603 / 01
165/269
Copyright © 2017 INVENTIO AG
5007
RM DATA COMMUNICATION DEVICE DEAD
The communication between the elevator control and the remote monitoring
data communication device (for example, modem) has failed
C1:The connection between the elevator control board and the remote
monitoring data communication device (for example, modem) is faulty
A1:Check data connection. Attempt to do a new call using menu 126.
Replace SCPU, ISCPU or SMICHMI/SMICFC board.
C2:Remote monitoring data communication device (for example, modem)
defective
A2:Replace remote monitoring data communication device
C3:The communication device was configured and working but the
communication to it was purposefully blocked to use the terminal
application (not the CADI) for more that 15 minutes.
A3:The terminal application shares the same physical serial port of the
modem. Set the menu 106 to 0.
5008
RM DATA COMMUNICATION DEVICE ALIVE
The communication between the elevator control and the remote monitoring
data communication device (for example, modem) has reestablished
5009
RM CLSD FAILURE
The communication line sharing device has detected a failure of its internal
electronics.
Note that the telealarm device is still operable, but back-calls from the control
center to the telealarm or telemonitoring device are not possible anymore.
C1:Device internal failure
A1:Replace the CLSD PCB
Code
Car Alarm Message
8001
CAR ALARM BUTTON PRESSED
Log alarm button states for enhanced diagnostic (misuse)
8002
CAR ALARM BUTTON RELEASED
Log alarm button states for enhanced diagnostic (misuse)
8003
CAR ALARM RELAY ACTIVATED
Log alarm relay states for enhanced diagnostic (misuse)
8004
CAR ALARM RELAY DEACTIVATED
Log alarm relay states for enhanced diagnostic (misuse)
8005
CAR INVALID ALARM DETECTED
Alarm button pressed or relay activated was received during the usual filtering
time
8006
CAR ALARM FILTERED
An alarm was received in normal mode but with the door not fully open or with
the car not traveling
8007
CAR VALID ALARM DETECTED
An alarm was received during the time when the alarm circuit discriminator is
not active.
8008
CAR ALARM FORWARDED
An alarm was received while the discriminator was active, the system tried to
free the passenger in time but did fail and thus the alarm is automatically
forwarded by the system.
Code