Schindler 3100/3300/6300
J 43402603 / 01
45/269
Copyright © 2017 INVENTIO AG
If TSD21 system, opening with triangular key will also block PEBO. Bring the elevator in
door unlocking zone and open the door without Triangular key.
3.6
Inspection and Emergency Recall Operations according
EN81-20 with BIC 7
Interlocks and
Priorities
–
The goal is to prevent unsafe interaction in case more than one inspection or
emergency recall operation is made active at the same time.
–
The interlock and priorities are defined according EN81-20 in order that the
operation from top-of-car or pit cannot be overruled by emergency recall operation.
–
The interlock and priorities are defined and guaranteed by the hardware circuit
design of the safety circuit and the switches and buttons of the inspection and
emergency recall panels.
Lock the control cabinet door. Go to the landing entrance
adjacent to the car level. Manually open the landing door
with the special triangular key: the passengers can exit the
car.
Close the landing door and ensure it is locked.
–
Call the repair service!
–
Ensure that landing door is locked again!
–
Ensure the main power switch is turned off!
Turn On the Manual Evacuation Switch (JEM).
Press the Manual Evacuation Button (DEM) at 3 second
intervals.
Have the passengers confirm that the car moves. If the car
does not move, turn OFF the switch for manual evacuation,
JEM.
Call the repair service.
When the blue floor indication LUET, lights up, push once
LUET and DEM buttons together.
Turn OFF the Manual Evacuation Switch (JEM).
LUET
OFF
ON
DEM
JEM
DEM
3 s
LUET
3 s
DEM
ON
JEM
OFF