5

AD-200 Offline Lock User Guide

 CONSTRUCTION ACCESS MODE

Construction Access Mode is used to allow access before the lock has 
been programmed, and for testing purposes.

•  Enabled by default.
•  The lock will remain in Construction Access Mode until the mode is 

cancelled as described below.

•  No audits are captured while lock is in Construction Access Mode.

Create the Master Construction Credential - Locks with 
Card Readers

The first card presented to a new lock automatically becomes 
the Master Construction Credential!

After you have created the Master Construction Credential, you can 
then use that card to add construction access mode user credentials.

 

Î

The Master Construction Credential will not grant access. It is used 
only to add additional credentials.

Add User Credentials - Locks with Card Readers

1. Present the Master Construction Credential to the lock. The 

Schlage button will light green.

2. Present the user credential to be added within twenty (20) 

seconds. The user credential will be added to the lock database.

3. To test enrolled user credential, present the credential. The Schlage button will blink and the lock 

will unlock.

 

Î

Credentials added using the Master Construction Credential will have normal 24/7 access.

Cancel Construction Access Mode

Do one of the following:

•  Authenticate or program the lock with the HHD. See the Schlage Utility Software User Guide for 

more information.

•  Reset the lock to factory settings. See Resetting To Factory Defaults on page 10 for more 

information.

•  Create a new master programming PIN code.

When construction mode is cancelled, the Master Construction Credential and all other 
credentials added using the Master Construction Credential will no longer function.

Locks with Keypads

In the factory default reset state, offline locks with keypads, with or without additional credentials, 
have a default PIN of 13579, which can be used for installation, testing and construction access. 
To test, enter default PIN. The Schlage button will blink and the lock will unlock. The default PIN is 
automatically deleted when a new programming credential is created, or the lock is programmed with 
the Schlage Utility Software (SUS).

TIPS

Use the same Master 
Construction Credential for 
all the locks in the facility.

If you present the first card 
to a new lock to create 
the Master Construction 
Credential and the card is 
not accepted, the lock has 
either been programmed 
or already has a Master 
Construction Credential.

If the Master Construction 
Credential cannot be 
located, or to put the lock 
back into construction 
access mode, reset the 
lock to factory settings. 
See Resetting To Factory 
Defaults
 on page 10 for more 
information.

Summary of Contents for AD-200-CY

Page 1: ...NE LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES OFFLINE LOCKS Para el idioma español navegue hacia www schlage com support Pour la portion française veuillez consulter le site www schlage com support P516 129 ...

Page 2: ... Mode 5 Locks with Keypads 5 Manual Lock Programming 6 Credential Types 6 Programming Legend 6 Using the Lock 8 Error Codes 9 Testing 9 Mechanical Testing 9 Electronic Testing 9 Resetting To Factory Defaults 10 LED Reference 10 Schlage Button 10 Optional Inside Push Button IPB 10 Batteries 11 Installing or Replacing Batteries 11 Low Battery Indications 11 Battery Failure Modes 11 External Power Su...

Page 3: ...11 or External Power Supply on page 12 for more information Outside lever is normally locked Inside lever always allows egress The lock maintains an audit trail of events Configured using the Handheld Device HHD See Handheld Device HHD on page 4 for more information Outside Schlage Button Outside Lever Keyway Inside Inside Push Button IPB Optional Thumbturn Inside Lever Battery Compartment Keypad ...

Page 4: ...ctronic operation See Testing on page 9 for more information 5 When ready to set up for normal use program the user credentials See Manual Lock Programming on page 6 for more information Î ÎProgramming the lock with the HHD will remove all credentials that were added using the master construction credential 6 Consult the Schlage Utility Software User Guide for information about configuring the loc...

Page 5: ...ancel Construction Access Mode Do one of the following Authenticate or program the lock with the HHD See the Schlage Utility Software User Guide for more information Reset the lock to factory settings See Resetting To Factory Defaults on page 10 for more information Create a new master programming PIN code When construction mode is cancelled the Master Construction Credential and all other credent...

Page 6: ...ozen until Freeze credential is presented again PIN 3 6 digits OR card Freeze PIN PIN 3 6 digits AND card Pass through Unlocks a lock momentarily regardless of state Overrides a lock in Freeze state PIN 3 6 digits OR card Pass through PIN PIN 3 6 digits AND card Programming Legend Symbol Description Programming Code Five digit code identical to programming credential code listed in the Credential ...

Page 7: ...e OR Programming Card Wait for to stop flashing between each step New PIN for PIN only OR New Card add another credential OR to finish Add Toggle Credential Programming Code OR Programming Card Wait for to stop flashing between each step New PIN for PIN only OR New Card add another credential OR to finish Add Toggle PIN Credential Programming Code OR Programming Card Wait for to stop flashing betw...

Page 8: ...ard Wait for to stop flashing between each step Credential PIN delete another credential OR to finish Change Relock Time Programming Code OR Programming Card Wait for to stop flashing between each step to add 1 second AND OR to add 5 seconds to finish 1 Other lights may show before the final confirmation Wait for the final confirmation before continuing to the next step USING THE LOCK After creden...

Page 9: ...the installation guide and correct any problems Mechanical Testing 1 Insert the key into the keyway and rotate the key or the key and the lever to open the door Operation should be smooth and the latch should retract 2 Insert the key into the keyway and rotate the key or the key and the outside lever to open the door Operation should be smooth and the latch should retract Electronic Testing 1 For ...

Page 10: ...ge Utility Software User Guide for more information Schlage Button Condition Lights Access denied 2 red blinks Access denied user outside time zone 4 red blinks Factory default reset Solid red while clearing memory then one second solid green when complete Waiting for PIN Card PIN Mode 0 only 5 left red with right green blinks then solid right green Low battery indicator AA batteries 9 left red bl...

Page 11: ...Coin Cell then normal indicator Replace batteries immediately to avoid battery failure Lock is intended to operate for 500 cycles in low battery condition Battery Failure configured by HHD No LED or beeps Valid credentials do not grant access Replace batteries immediately Mechanical override key must be used to unlock lock Battery Failure Modes Î ÎThe battery failure is set using the Handheld Devi...

Page 12: ...be connected to external power using a UL 294 Listed Power Supply capable of sourcing at least 250 mA 12 to 24 VDC Î ÎWhen powered with external power supply the lock will always fail As Is if power is lost Inside Polarity Required TROUBLESHOOTING For troubleshooting visit to www schlage com support ...

Reviews: