12 • Schlage • AD-200 user guide
OTHER programming
To complete
this action:
Perform the following steps:
Wait for
to stop flashing between each step!
1
2
3
4
5
Delete a
credential
Enter
Programming
PIN and
OR
Present
Programming
card
Enter
Enter the
PIN or
Card ID
Number to
be deleted
and
To delete
another Card
credential, go
back to step 3
OR
press again
to finish
Wait for
confirmation:
2 right green
blinks.
Change
PIN or Card
ID Number
length
Enter
Programming
PIN and
OR
Present
Programming
card
Enter
Enter
Enter
, , ,
OR for
desired PIN
length
Press
again to
finish
Wait for
confirmation:
2 right green
blinks.
Change
relock delay
period
Enter
Programming
PIN and
OR
Present
Programming
card
Enter
Enter
Each button
press adds to
the total delay
time
Example:
+ adds a
10 second delay
Press
again to
finish
Wait for
confirmation:
2 right green
blinks.
Error codes
L
All error codes are indicated on the Schlage button by a solid red left LED, and a
blinking green right LED. The number of green blinks indicates the error code.
Number of
green blinks
Error code description
Red
Left LED
Green
Right LED
1
Computer programming error (not complete).
2
Too long programming/user code entered.
Programming code must be five (5) digits. User code
length cannot exceed six (6) digits.
3
Memory full, too many codes. Delete some codes.
4
Programming code cannot be deleted, only changed.
5
Programming code entries do not match.
Programming code not changed.
6
Invalid command. Invalid function code entered.
7
Code not found.
8
Code too short. Programming code length must be five
(5) digits. User code minimum length is three (3) digits.
9
Not a unique code.
10
Manual programming not allowed.