15 • Schlage • AD-200 user guide
Reset to factory defaults
All information in the lock will be deleted and reset to factory defaults!
Level 1 factory default reset
L
Level 1 factory default reset will delete configurations and settings in the main
controller in the lock.
L
Main controller configurations that will reset to factory default include:
programming and user codes.
L
Level 1 factory default reset
will not
reset configurations and settings in the reader.
1. Remove the top inside cover.
2. Press and hold the Schlage button until two (2) beeps sound (10 seconds).
3. Release the Schlage button.
4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One
beep will sound and one red blink will occur with each press.
5. The Schlage button and IPB will both light green for one second and a one-second beep
will be heard. This indicates that the lock has been reset.
L
If the IPB is not pressed 3 times within 10 seconds, two beeps with two red
blinks indicate timeout.
6. Replace the top inside cover.
Level 2 factory default reset
L
Level 2 factory default reset will delete all configurations and settings in the lock
and the reader.
L
Reader configurations that will reset to factory default include: keypad format,
magstripe reader track, beeper on/off, and contactless card.
L
Days in Use counter and lock type configurations will not reset.
To complete Level 2 factory default reset, repeat steps 2 through 5 above
within 10
seconds of the confirmation signals of Level 1 factory default reset.
If more than 10
seconds pass after the confirmation signals of Level 1 reset, then Level 1 reset will be
repeated.