4.1.5
ADDING THE CONTROL PANEL & DSI BOARD IN SYSTEM GALAXY
Add the 635 Controller (access control panel) to the loop/cluster:
Open the Controller Properties screen:
click on the Controller button on the toolbar
,
{
Or from the menu, select
Configure > Hardware > 635 Controller
}
When the Controller Properties screen opens,
select the Loop/Cluster name
you just created in the
previous step.
1. Click [ Add New ]
to add the controller.
2. Enter the
Controller serial number
(found on the CPU board). This can be a valid serial
number of any CPU in this loop/cluster.
3. Enter a user-friendly descriptive Name
for the control panel. The software automatically
assigns a controller name – you can / should change that to a name that logically describes the
location or purpose of the panel (i.e. Lobby controller, or East Wing, 1
st
floor, etc.) for
administration and future maintenance purposes.
4. Click the [Get Board Info] button:
the Board Info screen will open and display the list of boards
in that panel.
5. Click the [Save]
button to add the boards.
6. Configure Alarm I/O Groups and other Options as needed. You would only use Alarm I/O
Groups here if you were monitoring the controller alarm events.
7. Click [ Apply ]
to save the configuration.
Figure 10 – Controller Properties: Configuring a 635/600-series Controller
System Galaxy Integration to Schlage AD400/AD300
Page 31