9
AD-400 /AD-401 Networked Wireless Lock User Guide
RESET TO FACTORY DEFAULT SETTINGS
!
All information in the lock will be deleted and reset to factory defaults!
Level 1 Factory Default Reset
Level 1 factory default reset will delete confi gurations and settings in the main controller in the lock.
Level 1 factory default reset will not reset confi gurations and settings in the reader.
1. Remove the top inside cover.
2. Press and hold the Schlage button until two (2) beeps sound (10 seconds).
3. Release the Schlage button.
4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One beep will
sound and one red blink will occur with each press.
5. The Schlage button and IPB will both light green for one second and a one-second beep will
sound to confi rm that the lock has been reset.
If IPB is not pressed 3 times within 10 seconds, two beeps with two red blinks indicate timeout.
6. Replace the top inside cover.
Level 2 Factory Default Reset
Level 2 factory default reset will delete all confi gurations and settings in the lock
and
the reader.
Reader confi gurations that will reset to factory default include: keypad format, magstripe reader
track, beeper on/off, and contactless card.
Days in Use counter and lock type confi gurations will not reset.
To complete Level 2 factory default reset, repeat steps 2 through 5 above
within 10 seconds of
the confi rmation signals of Level 1 factory default reset
. If more than 10 seconds pass after the
confi rmation signals of Level 1 reset, then Level 1 reset will be repeated.