10  •  Schlage  •  CO-250 user guide

Troubleshooting

Problem

Possible cause

Solution

The lock beeper does 

not sound and the 

keypad does not light 

when the Schlage 

button is pressed.

The reader may not be 

properly seated into the 

front escutcheon.
The reader connector may 

have bent pins.
The through door ribbon 

cable may not be properly 

plugged in.
The battery or wired 

power may be improperly 

connected.
The batteries may be 

inserted with incorrect 

polarity.

Check that the reader is fully seated 

into the front escutcheon.
Check that there are no bent pins in 

the reader connector.
Check that the through door ribbon 

cable is plugged in correctly. The red 

wire should be on the left and not 

pinched in the door.
Check that the battery or wired power 

is connected correctly.
Check that the batteries are inserted in 

the correct polarity.

Refer to the installation instructions 

that came with the CO-250 lock, or 

this user guide for details on the above 

mentioned procedures.

The connection 

with the SUS is not 

successful.

The triangles on the 

outside lock assembly 

(cylindrical and mortise 

locks only) may not be 

properly aligned.

Check the outside lock assembly 

(cylindrical and mortise locks only). 

The triangles on the back of the lock 

assembly must be properly aligned.

Refer to the installation instructions 

that came with the CO-250 lock for 

details.

The reader is not 

working.
The Smart card is not 

reading.
The magnetic swipe 

card is not reading 

correctly (no beeps 

or blinks).

The through door ribbon 

cable may be pinched.
The Smart card default of 

the card reader may not be 

correct for the Smart card.
The “Mag Track in Use” 

default for all Magnetic 

Card Credential Readers 

is “Track2”. The magnetic 

swipe card data may be on 

Track1 or Track3.

Check that the through hole ribbon 

cable is not pinched.
Change the Smart card format using 

the SUS. Select CO-250 “Lock 

Properties”, “Reader” tab, and “Smart 

cards in use”.
Use the SUS to change “Mag 

Track in Use”. Select CO-250 “Lock 

Properties”, “Reader” tab, and “MAG 

Card Track selection”.

Refer to the installation instructions 

that came with the CO-250 lock, or 

the SUS user guide for details on the 

above mentioned procedures.

The LEDs and 

beeper indicate an 

incompatible reader 

(2 red blinks and 2 

beeps with each card 

or key press, or 5 red 

blinks and 5 beeps 

on power-up).

The reader is not the 

original reader matched 

with the lock at the factory.

The lock must be installed with the 

original reader that came with the lock.

Summary of Contents for CO-250

Page 1: ...CO 250 Offline lock user guide Instructions for programming CO Series offline locks Para el idioma español navegue hacia www schlage com support Pour la portion française veuillez consulter le site www schlage com support ...

Page 2: ...ry defaults 7 Level 1 factory default reset 7 Level 2 factory default reset 7 Batteries 8 To install or replace alkaline batteries 8 Low battery indications 8 Battery failure modes 9 LED reference 9 Schlage button 9 Optional Inside Push Button IPB 9 Troubleshooting 10 FCC statements 11 This product is compliant of UL294 and ULCS319 standard This product s compliance would be invalidated through th...

Page 3: ... lever is normally locked Inside lever always allows egress The lock maintains an audit trail of events The lock is configured using the Schlage Utility Software SUS See Schlage Utility Software SUS on page 4 for more information Outside Schlage Button Outside Lever Keyway Inside Thumbturn Battery Compartment Optional Inside Push Button Inside Lever Mag Swipe Reader Mag Swipe Keypad Reader CO 250 ...

Page 4: ...of the system 4 Test the lock for proper mechanical and electronic operation See Test lock operation on page 6 for more information 5 Consult the Schlage Utility Software SUS user guide for information about configuring the lock 6 Familiarize yourself with the information contained in this user guide Save this user guide for future reference Schlage Utility Software SUS The Schlage Utility Softwar...

Page 5: ...r construction credential will have normal 24 7 access Cancel construction access mode Construction access mode may be cancelled by one of the following methods load a door file using the SUS reset the lock to factory settings see Reset to factory defaults on page 7 for more information When construction mode is cancelled the master construction credential and all other credentials added using the...

Page 6: ...and the door will unlock for the preset relock delay period After the relock delay period the lock will relock and the Schlage button will blink red If the lever retracts and holds the latch through the relock delay period then the Schlage button will light green until the lever is released Test in normal operation mode 1 Present a valid credential The Schlage button will blink green a beep will s...

Page 7: ...the key until confirmation signals are observed the Schlage button light will turn off one second and a one second beep will sound After confirmation signals release the mechanical key 4 The Schlage button will light green for one second and a one second beep will sound to confirm reset to factory defaults L L If the mechanical key is not rotated within 10 seconds two beeps and two red blinks indi...

Page 8: ...teries are incorrectly replaced Replace only with the same or equivalent type Dispose of used batteries according to the manufacturer s instructions This product has been evaluated for ULC S319 compliance with Duracell Procell PC1500 AA alkaline batteries and Panasonic CR2025 lithium coin cell For installations requiring ULC S319 these battery models should be used CY MS MD 993 Plug MUST Be on Rig...

Page 9: ...e relocking 1 red blink SUS authentication Left green solid USB active with no physical connection Left green blinking Waiting for PIN Card PIN 5 left red with right green blinks then solid right green An incompatible reader is on the lock 2 red blinks and 2 beeps with each card or key press or 5 red blinks and 5 beeps on power up Optional Inside Push Button IPB Action Lights Office Mode Allows lo...

Page 10: ...heck the outside lock assembly cylindrical and mortise locks only The triangles on the back of the lock assembly must be properly aligned Refer to the installation instructions that came with the CO 250 lock for details The reader is not working The Smart card is not reading The magnetic swipe card is not reading correctly no beeps or blinks The through door ribbon cable may be pinched The Smart c...

Page 11: ...th Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Page 12: ... Allegion 2014 Printed in U S A P516 272 Rev 03 14 f Customer Service 1 877 671 7011 www allegion com us ...

Reviews: