Silent mode:
Disables the tone sound.
Status indicators:
Located on exterior assembly.
Definitions
Master mode:
The master mode could be entered by entering
[**Master PIN Code #] to program the lock.
Master PIN code:
The master PIN code is used for programming
and for feature settings.
Shutdown time:
The lock will shutdown for a default of 3 minutes
and not allow operation after the wrong code
entry limit (5 times) has been met. When the unit
is in shutdown, the light will flash if you are trying
to use the keypad.
User PIN code:
The user PIN code operates the lock. Maximum
number of user PIN codes is 20.
Fake PIN code:
Random numbers that are added before or
after the user PIN. This prevents the user PIN
from being exposed.
Reset button:
After reset operation, the lock will be restored to
factory default settings, all user credentials will
be deleted. Refer to page 11 for instructions on
how to reset your lock.
Passage mode:
The lock can be switched to passage mode by
toggling the switch on the internal side. In this
mode, it is unlocked inside/out and you may
enter freely. You may still lock the unit externally
by holding any key for 2 seconds. It will resume
passage mode when unlocked via PIN or key
override until the passage mode switch is shifted
to the locked position. Note: Enabling and
disabling passage mode can only be done on the
internal side of the unit via the switch.
Item
Specifications
Notes
External assembly
165mm (L) x 70mm (W) x 22mm (D)
196mm (L) x 73mm (W) x 28mm (D)
AA alkaline battery x 4
(Operation voltage: 4.6~6.0V)
Operation temperature:
-20ºC to 55ºC
Lasts up to one year
(10 times open/close per day)
Internal assembly
Battery
Hardware specifications