Operational Recommendations / Dimensions
Operational Recommendations:
The models with a knob operate the deadbolt much like a key, therefore more time to operate the dead-
bolt/latch might be desired.
See programming guide to change the relock time delay to a longer time.
The Adams Rite® 4710 can be operated by the knob to achieve the ‘hold back’ condition where the latch
is held in the unlatched position for passage mode. To do this, enter a code/iButton, push the latch all the
way in and rotate the knob (counterclockwise if the latch is to your left or clockwise if the latch is to your
right). When you feel a little resistance, turn a little harder. This will move a part to keep the latch from
springing out. To reverse the condition and release the latch, enter a code/iButton again and turn the knob
(clockwise if the latch is to your left and counterclockwise if the latch is to your right). This will move the
part out of the way and release the latch.
Dimensions: