KC9232/KC9232-2 & KC9233/KC9233-2 INSTALLATION
Door Preparation
57041-D Page 4 04-11-2007
Door Preparation
Door Conditions:
Installation may require the use of a cover plate (
a
) to cover the holes left in the door.
If the existing pull (
b
) must be removed, Ives offers a compatible pull.
>Schlage Cover Plate P/N: KC9000-KRP
>Ives Pull P/N: 8190-18-xxx (xxx = finish)
b
a
For factory prepped doors
, use dimensions
shown. Dimensions are referenced from center
of 1-1/4” cylinder hole. Backset is determined
by the Adams Rite® lock.
When installing new Adams Rite® locks
, do
not install outside cylinder because this trim
replaces it. Do not install face plate at this time
because access to the cylinder set screw in the
lock will be required during installation.
3-31/32”
(3.962”)
2-45/64”
(2.697”)
Backset is determined by
the Adams Rite® lock.
6-21/32”
(6.656”)