Page 1: ...ng M492 Max Security UL1034 and 10C 1500lb and 3hr rating TRIMS Basic Auto Voltage Selection AVS for 12 or 24VDC Plus Basic features Door Position Switch DPS Magnetic Bond Sensor MBS Relocking Time Delay RTD LED Status Indicator LED and Anti Tamper Switch ATS UL Requirements Units shall not impair operation of panic hardware mounted on door Units shall not impair intended operation of an emergency...

Page 2: ...r Coil M422 1 500 0 760 500 M452 1 500 0 760 1000 M492 1 300 0 700 1500 LOCK INSTALLATION 1 PREPARE FOR INSTALLATION 1a Lock Orientation Locks should be installed with wiring covers in the middle so the magnet in one of the locks must be reoriented Shown from Exterior Magnet Magnet Wiring Covers ...

Page 3: ...ng cover and end blocks Rotate magnet end blocks and wiring cover as shown then reassemble End Block Magnet End Block Magnet Wiring Cover 1c Place Template and Mark Holes Place template on top centerline of doors Mark holes and prepare them per template ...

Page 4: ...e Cover 2b Drill Hole for MBS Indicator Bottom 0 75 19 mm 6 mm drill bit M420 0 50 13 mm M450 490 0 75 19 mm 0 25 6 mm hole 2c Install MBS Indicator 3 INSTALL ATS PLUS MODELS ONLY 3a Remove End Block and Wiring Cover a c b 3b Install ATS and Reassemble d e f ATS ...

Page 5: ...hown Outside 2x 5 INSTALL MOUNTING BRACKETS INTO FRAME 5a Attach Mounting Brackets Temporarily Install alignment tool onto brackets Install four 4 screws into slotted holes and partially tighten OUTSIDE Wires Alignment tool Actual Size Metal Wood ...

Page 6: ...ss magnets to fully engage with armatures Mark brackets on ends Mark here both sides Press magnets to armatures INSIDE 5f Remove Magnet and Snug Two 2 Outer Screws OUTSIDE Snug these two screws 5g Align Center of Brackets Using Alignment Tool Loosen two 2 innermost screws Place alignment tool over brackets Tighten all four 4 screws OUTSIDE Loosen these two screws ...

Page 7: ...hrough 5h Magnets making full contact with armatures INSIDE 5i Prepare Additional Holes Install alignment tool on brackets Fully tighten four 4 screws Drill eight 8 remaining holes Use 10 24 tap if metal is reinforced Fully tighten four screws OUTSIDE 5j Install Eight 8 Screws Remove alignment tool Install and fully tighten eight 8 screws OUTSIDE Actual Size Reinforced Metal Sheet Metal ...

Page 8: ...MAGNETS TO MOUNTING BRACKETS 6a Slide One Magnet onto Bracket OUTSIDE 6b Install Joining Block into Lock 6c Slide Second Magnet onto Bracket Align with joining block 6d Secure Locks with Four 4 Screws Actual Size ...

Page 9: ...TO BOARD STANDARD MODEL 7a Review Wiring Connections TB1 Mag Lock Board DC DC From Magnet TB1 Mag Lock Board DC DC From Magnet DC DC 7b Connect Wires to Boards From Door Frame DC Power Wires From Magnet 7c Install Covers ...

Page 10: ... Normally Open NO Wiring in Parallel Switch position will be closed when doors are closed and locked To be used with normally open terminals Switch position will be open when doors are closed and locked To be used with normally closed terminals DC Power NO NC C NO NC C DC DC MBS 1A 30VDC Resistive DPS 0 25A 30VDC Resistive NO NC C NO NC C DC DC Normally Closed NC MBS MBS In Out Normally Closed NC ...

Page 11: ...S RTD Adjuster RED Polarized Black Red Note Two MBS plugs are interchangeable Min Time Max Time Mag Lock Board 8c Connect Plugs to Boards From Magnet From LED From MBS From MBS 8d Connect ATS Wires ATS NC violet NO gray C white Switch Rating 1A 30VDC Resistive 8e Install Covers ...

Page 12: ... 2011 Schlage Lock Company Printed in China 44487304 Rev 04 11 c ...