background image

M400 Series
Electromagnetic Locks

Installation Instructions for Single Locks
M420, M450, M490

FEATURES

Automatic Voltage Selection (AVS)

Magnet immediately detects 12VDC or 24VDC when power 
is connected.

Anti-Tamper Switch (ATS)

An indication is provided should the magnet cover become 
unsecured from lock.

Magnetic Bond Sensor (MBS)

Detects proper bond between magnet and armature. It can 
be monitored remotely and locally with an LED.

LED

Provides local indication of MBS status.

Door Position Switch (DPS)

Indicates whether door is open or closed. this feature is used 
in conjunction with the MBS.

Relock Time Delay (RTD)

Relock time can be changed. Range is 1 - 30 seconds.

MODELS

M420 (Traffi c Control)

UL1034 and 10C/500lb and 3hr rating

M450 (High Security)

UL1034 and 10C/1000lb and 3hr rating

M490 (Max Security)

UL1034 and 10C/1500lb and 3hr rating

TRIMS

Basic

Auto Voltage Selection (AVS) for 12 or 24VDC

Plus

Basic fe Door Position Switch (DPS), Magnetic Bond 
Sensor (MBS), Relocking Time Delay (RTD), LED Status 
Indicator (LED) and Anti-Tamper Switch (ATS)

UL Requirements:

•  Units shall not impair operation of panic hardware mounted on door.
•  Units shall not impair intended operation of an emergency exit.
•  Units/Models are intended to be connected to UL Listed Equipment, not 

intended for Burglar or Fire Alarm Initiating or Indicating Devices.

•  Ambient Conditions - “For Indoor Use Only”

This device complies with part 15 of FCC rules.

Operation is subject to following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including any 

interference that may cause undesired operation. Changes or modifi cations 
not expressly approved by party responsible for compliance could void 
user’s authority to operate equipment.

Summary of Contents for M420

Page 1: ...ng M490 Max Security UL1034 and 10C 1500lb and 3hr rating TRIMS Basic Auto Voltage Selection AVS for 12 or 24VDC Plus Basic features Door Position Switch DPS Magnetic Bond Sensor MBS Relocking Time Delay RTD LED Status Indicator LED and Anti Tamper Switch ATS UL Requirements Units shall not impair operation of panic hardware mounted on door Units shall not impair intended operation of an emergency...

Page 2: ...oil M420 0 750 0 380 500 M450 0 750 0 380 1000 M490 0 650 0 350 1500 LOCK INSTALLATION 1 PREPARE FOR INSTALLATION 1a Determine Proper Magnet Orientation Magnet should be placed opposite of door hinges Magnet Wiring Cover LHR Door Shown from Exterior Magnet Wiring Cover RHR Door Shown from Exterior ...

Page 3: ...Block Magnet End Block with screw hole Rotate magnet end blocks and wiring cover as shown then reassemble Magnet Wiring Cover End Block with screw hole 1c Place Template and Mark Holes Place template on top corner opposite of hinges Mark holes and prepare them per template LHR RHR ...

Page 4: ...er 2b Drill Hole for MBS Indicator Bottom 0 75 19 mm 6 mm drill bit M420 0 50 13 mm M450 490 0 75 19 mm 0 25 6 mm hole 2c Install MBS Indicator 3 INSTALL ATS OPTIONAL PLUS MODELS ONLY 3a Remove End Block and Wiring Cover a c b 3b Install ATS and Reassemble d e f ATS ...

Page 5: ...all as Shown Outside 2x 5 INSTALL MOUNTING BRACKET INTO FRAME 5a Attach Mounting Bracket Temporarily Install two middle screws into slots and partially tighten Partially tighten Pull wires OUTSIDE Actual Size Reinforced Metal Sheet Metal ...

Page 6: ... Press magnet to armature INSIDE Mark here 5e Fully Attach Bracket Remove magnet from bracket Check bracket alignment with marks Fully tighten two screws in slotted holes Drill four 4 remaining holes Fully tighten all screws Fully tighten all screws Drill four 4 holes Use 10 24 tap if metal reinforced Check alignment OUTSIDE Actual Size Reinforced Metal Sheet Metal ...

Page 7: ... Secure with Screws Actual Size 7 CONNECT WIRING TO BOARD STANDARD MODEL 7a Review Wiring Connections TB1 Printed Circuit Board DC Power DC DC From Magnet 7b Connect Wires to Board From Door Frame DC Power Wires From Magnet 7c Install Cover ...

Page 8: ...ed state DPS 0 25A 30VDC Resistive Contacts shown in open door state From Magnet Printed Circuit Board From LED From MBS From MBS RTD Adjuster RED Polarized Black Red Note Two MBS plugs are interchangeable Min Time Max Time 8b Connect Wires to Board From Magnet From Door Frame Multi Wire Cable From LED From MBS 2 From MBS 1 8c Connect ATS Wires ATS NC violet NO gray C white Switch Rating 1A 30VDC ...