Page 1: ...USER MANUAL Notice Please read this manual before installation and operation S 7800 DIGITAL PUSH PULL DOOR LOCK WITH FINGERPRINT READER ...

Page 2: ...wash affected skin area with soap and water immediately Do not clean the product with ammable materials such as alcohol benzene or thinners Such materials may damage the surface of the lock or cause a re Batteries should not be exposed directly to heat sources or submerged in water because they may leak or explode resulting in severe damage Do not use damaged batteries Do not allow the battery ele...

Page 3: ...ow to register delete cards fobs in normal mode 13 How to register delete fingerprints in normal mode 13 How to register delete PIN codes in safety mode 14 How to register delete cards fobs in safety mode 14 How to register delete fingerprints in safety mode 14 Entering manager PIN code in safety mode 14 Entering manager cards fobs in safety mode 14 Deleting manager card s fobs in safety mode 14 H...

Page 4: ...Auto relock function If users do not open the door after unlocking the device it will lock itself automatically Double lock function When double lock function is activated the door cannot be opened from the outside even with the registered card PIN code or fingerprint Override key can still be used Mute function Door will not emit any sound when mute is activated Battery level indicator and alarm ...

Page 5: ...ople you may not want to show your PIN code to them In this case you may press any numbers randomly and then enter your PIN code at the end and you will still gain access Normal mode safety mode Normal mode is ideal for new users or low security environments Safety mode provides a higher security level via use of a manager PIN code Allows individual register and delete function which is not provid...

Page 6: ...Ⅰ Before using 6 Productcompositionandcomponents Remote key Part RP 10 Optional Communication pack Part RXP 10 Optional Screws CARD FOB 1 6 9 10 7 11 12 14 15 8 13 2 3 4 5 PATCH ...

Page 7: ...ne 9 Handle shaft 70 5mm W X 8mm H X 8mm D 40 50mm door 10 Handle shaft M 101 7mm W X 8mm H X 8mm D 70 90mm door 11 Handle shaft clip 2 of 12 Key tail plate 1 of 13 Screws 1 set 14 Communication pack Communication pack Optional 15 Remote key Remote key Optional Note door thickness range is 40mm 90mm Factorysettings Item Setting status Ref page Auto Manual lock mode Auto lock 11 Language English Ch...

Page 8: ...tatus and checking battery Touch type numeric pad Emergency cover Function icon Mute function Safety handle Battery replacement indicator Trespass alarm function Wireless interlock Card keys Card fob patch Mechanical keys External emergency power supply terminal When batteries are flat lock may be operated and unlocked by contacting 9V battery on terminals Emergency key cylinder Door may be opened...

Page 9: ...e Manual locking button Button to lock the door manually Double lock function button Button to set double locking mode Safety handle jog button Refer to explanation below Manual safety handle switch To release safety handle function manually when safety handle jog button is out of order or battery has died How to set the safety handle function Hold down CLOSE for 5 seconds The safety handle functi...

Page 10: ...the handle and open the door How to use random security coding function RAN DOM CODE C Howtoreplacebatteries If battery lamp is flickering RED and alarm sounds open battery cover and replace all 8 batteries 1 5V AA size LR6 alkaline N button S button Option button Press Press Touch the front pad C PIN code Card key Fingerprint UC User code MC Manager code RC Registration code Trespass alarm Unlock...

Page 11: ... locking mode In auto locking mode door will be locked automatically after closing Manual locking mode In manual locking mode door will be locked by pressing manual lock button after closing How to select the language English 3 C or 1 Chinese 3 C or 2 1 Auto locking mode When the door is closed door is locked with beep sound automatically 2 Manual locking mode Setting manual mode Press manual lock...

Page 12: ...gency release Push to the right manual safety handle switch C Card key 1 How to set the safety handle function from outside 2 How to set the safety handle function from inside how to release 1 Auto locking function 2 Auto relocking function Howtosetdoublelockingfunction Auto lockingfunction auto relockingfunction Cancel Set up Press double lock button for 3 second Press manual locking button When ...

Page 13: ...UC UC How to change from normal mode to safety mode Safety mode 3 sec UC MC MC Normalmode Normal mode 1 2 3 4 5 6 7 8 9 10 REG PIN code 1 4 RC Card key 1 5 Finger print 1 6 DEL All Card key 2 5 All 2 6 Repeat highlighted part of diagram above for continuous register or delete Howtochangenormalmode safetymode Normal mode ideal for new users or low security environments Safety mode higher security l...

Page 14: ...Cor Card registration number 2digits Finger print 1 6 MCor Fingerprint registration number 3 digits 3 times DEL All card key 2 5 MCor Individual card key 3 5 MCor Card registration number 2digits All fingerprint 2 6 MCor Individual fingerprint 3 6 MCor Fingerprint registration number 3 digits Safety mode manager Change Manager code 8 4 MCor RC RC REG Manager card key 8 5 MCor DEL All manager card ...

Page 15: ...me Vol up C or 3 7 Vol down 9 Status checking guide Voice guide C or 4 Check battery capacity Voice guide C or 5 Safety handle function Set up C or 8 Warning function against hacking Operate Wrong PIN code three times unregistered card three times unregistered fingerprint five times Warning alarm function against trespass by force PIN code C Card key C Additionalfunctions ...

Page 16: ...e the batteries 2 Install the wireless communication pack on the connected terminal 3 Insert the batteries after confirming the direction of and Battery Option button Remote unlock Remote lock To register to delete remote key communication pack REG Remote key 1 C or or DEL All remote key 2 C or To lock to unlock by remote key Unlock Lock Repeat highlighted part for continuous register or delete Po...

Page 17: ...MEMO ...

Page 18: ......

Page 19: ......

Page 20: ...tralia Pty Ltd Phone 1800 098 094 www allegion com au Allegion New Zealand Limited Phone 0800 477 869 www allegion co nz Allegion Southeast Asia Pte Ltd Phone 65 6488 2562 www allegion com S 7800 USER MANUAL 04 18 ...