4.2  Special Servicing Procedures and Equipment subject to Service 
Life Limitations 

 

Special Servicing Procedures 

 
At regular intervals of 5 years, the sealing rings and groove sealing rings of the 
water ballast valves must be checked, and replaced if required (see Fig. 2.4-1). 
 
At regular intervals of 6 years the brake line hose of the hydraulic wheel brake 
must be replaced. Should this hose be found to be in good condition, it need not 
be replaced, on condition that its condition is checked at least every 100 flying 
hours. 
 
 

Equipment subject to Service Life Limitations 

 
Tow Releases 
 
The tow release fitted at the C.G. is model TOST "Europa G 88" or "G 72" or 
"G 73" respectively , 

The aerotow release is either the model TOST “E 22” (if installed at the tip of the 
fuselage nose) or one of the models TOST "E 85" or "E 72" or "E 75" (if installed 
between pedals and stick).  

The above TOST tow releases must comply with the service life limitations 
between inspections as laid down in their respective authorized release certifi-
cates. 

The relevant "Operations and maintenance instructions" issued by the manufac-
turer TOST must be complied with. 