Schleuniger CCM 1200
Connections
Mains connection
•
Mains connection single-phase, earthed (2P + E)
•
115, 230, 240 V / 50 - 60 Hz
•
Power consumption maximum 80 VA
•
The CCM 1200 operates
without
compressed air.
The fuse holder (Figure 2, Page 23) also houses the voltage selector. See Page 31. for details
on how to change the fuses. The procedure for changing the voltage is described on Page 30.
Prefeeder Input
An electric or mechanical prefeeder can be connected to the prefeeder input. This allows the
cable feed to be monitored and processing to be stopped automatically in the event of an
emergency. With Schleuniger equipment the corresponding connector cable is supplied with the
prefeeder. Otherwise a D-Sub connector can be wired as follows:
13
12
11
10
Figure 4. Control contact S1
Once the D-Sub connector has been inserted and the control contact S1 is closed you can start
the CCM 1200 in the normal way. When the control contact S1 opens automatic processing is
interrupted and the error message CABLEFEEDER STOP appears in the display. Once the
control contact S1 has closed again the programme can be continued by pressing [run].
Prefeeder
CCM 1200
Prefeeder
Input
D-Sub cable
Prefeeder Input
S1