Schleuniger CCM 1200
25
Wire Marker
The Wire Marker connection enables the CCM 1200 to also receive and process control signals
from an up or downline machine. This control input can be used for example for the following
purposes:
•
Connecting a wire marker in order to receive return messages from it
•
Connection of a pedal for single piece production
The relevant control contact is closed in order to activate the various functions. Please
only
use
potential-free, gold-plated contacts (relays) or opto-couplers for this purpose.
Pause function
If the control contact S2 is open the CCM 1200 can be started in the normal way.
Figure 5. Pause function
If the control contact S2 is closed then the feed is interrupted but the LED above the [run] key
stays on. If the control contact S2 is opened again then the feed and processing is continued.
This function is particularly suitable for use with the connected wire marker. The CCM 1200 stops
the processing and issues the mark command to the wire marker. During the marking process the
wire marker triggers the control contact S2 to close so that the automatic unit does not continue
to feed the material forwards.
S2
+ 24
1
2
4
5
Socket Wire Marker