28
Schleuniger CCM 1200
Control Panel
All the functions of the control panel keys are explained below. In these Operating Instructions the
keys to be pressed are written in square [brackets].
Figure
8.
Control
panel
[quantity]
The [quantity] key is used to select the quantity (0 to 999’999). If you press the
key then a cursor appears in the display. The cursor flashes until you have keyed
in the required quantity on the numerical keyboard and confirmed it by pressing
[enter].
[length]
The [length] key is used to select the length of the pieces to be cut. If you press
the key a cursor appears in the display. The cursor flashes until you have keyed in
the required length on the numerical keyboard and confirmed it by pressing [enter].
The length can be entered in mm or in 1/100" (See the STOP key).
[correct - ]
[c]
Depending upon the composition of the material to be cut deviations in length can
occur when the material is being fed. The pieces are then either slightly too long
or too short. If the measurement is too short then press [c ] and enter the
difference from the programmed length. If the measurement is too long press the
[correct - ] and enter the difference from the programmed length. Confirm the
entry each time by pressing [enter]. Once you have programmed a corrected
value then a + or - symbol appears in the display under [length].
In order to display the entered corrected value press [c] or [correct - ]. By
pressing [enter] the set value is retained, pressing [clear] and [enter] the value is
set to 0.
If you select a new length by pressing [length] the value entered under [correct] is
deleted.
[clear]
Pressing [clear] sets a value to 0.