Schleuniger CCM 1200
31
Replacing the mains fuse
Switch the master switch off and disconnect the mains plug from the power supply.
•
Lever out the fuseholder with a screwdriver (Figure 9, Page 30).
•
Always replace both fuses:
100 VAC, 115 VAC = 2 x 3,15 A/T
230 VAC, 240 VAC = 2 x 1,6 A/T
•
Insert the fuseholder.
•
Insert the mains plug into the power supply.
Changing the unit of measure
There are two setting options for changing the unit of measure to „mm“ or „inch“:
•
Temporary change
•
Changing the standard setting
With a temporary change the new unit of measure in each case only remains active until you
switch the master switch off and back on. For details on how to change the unit of measure
temporarily see the section entitled „Control panel “ on Page 28 under the description of the
[STOP] key. Any change in the standard setting may only be carried out by specially trained
personnel (Page 43).
Display language
•
Hold down the two [speed] keys when switching on the automatic unit. (Or press [5] if the
automatic unit is already on).
•
The word
CODE ?
appears in the display
•
Release the [speed] keys.
•
Enter "40, 41, 42 or 43".
40 = English
41 = German
42 = French
43 = Italian
•
First press [enter] then [STOP]