14. Appendix
Reference Manual |Edition 4.0 (10-2013) |EcoCut 3300
89|108
Parameter
Max. ratings
Min.
Typ.
Max.
Output voltage
V
SUPPLY
I
SUPPLY
≤
1.35 A
22.8
24
25.2
V
Output current
a
I
SUPPLY
-
-
1.35
A
Impulse withstand voltage
U
IN_SRG
I
IN_SRG
≤
1 @
IN_SRG
≤
10 µs
-
-
40
V
a ) The sum of all the output currents of all supply connections.
Protection against faults and malfunction
The +24 V outputs must not be connected to external power supplies.
Machine
Peripheral device
Power supply
Controller
e. g. PLC
Shielding recommended for long cables
Fig. 19: Avoiding short circuit
To avoid ground loops it is recommended that the signal on the peripheral device is galvanically decou-
pled. This can be achieved through, e. g. relays or opto couplers (already available in most PLC‘s). In heavy
EMV loaded areas, we recommend the use of shielded connections.