10. Diagnostics / troubleshooting
56|108
Reference Manual |Edition 4.0 (10-2013) |EcoCut 3300
10.4
ERROR MESSAGES
Error
Text
Description/action
1
Safe mode! No production possi-
ble.
Initializing could not be performed.
2
Internal error.
3
HotStamp timeout.
HotStamp device is not responding. Message from
production.
4
No feedback from HotStamp.
HotStamp device is not responding. Message from
diagnosis.
5
Blade blocked! Production can-
celed.
No feedback from motor. The cutting procedure
could not be completed fully. Blocked by too thick
wires.
6
No wire! Production canceled
Wire end switch detects no wire.
7
No more memory. Delete first.
The wire memory already contains 100 wires. You
have to delete existing wires to be able to save new
ones.
8
Invalid name, empty or used: \\ / :
* ? \" < > |
File name invalid. Characters like / : * ? \" < > | are
not allowed.
9
File not found.
A file which is missing was entered.
10
No prefeeder connected.
Appears on diagnose if a prefeeder is being tested
although none is connected.
11
No pedal detected.
Appears on diagnostic if a pedal is being tested but
none is connected.
12
RAM corrupted. Machine stopped.
Replace hardware.
The internal memory changed unintended. This
indicates an error with the FRAM. Hardware
exchange is indispensable.
13
Actual value not in range.
%-correction calculation. If the value is beyond the
permitted range, the calculation is not carried out.
14
Enter correct password!
The password for the selected user level is wrong.
15
Password confirmation wrong!
While changing the password the confirmation was
entered incorrectly.
16
Illegal operation for current user
level.
The selected function is not allowed with the
present user level.
17
Communication error to PPI
The PPI is not implemented.
18
Prefeeder blocked!
The prefeeder is not switched on or the wire entry
area is blocked.
19
Tow error beyond the limit.
Pulling force too high. Check the wire entry area.
20
Over temperature fault Production
canceled.
Electronics on over temperature. The production is
temporarily interrupted. Switch off the machine
and wait for five minutes.
21
Cutting motor could not brake.
Motor control unit on error. Switch off and then on
again the machine.
Summary of Contents for EcoCut 3300
Page 8: ...Table of contents 8 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 22: ...4 Product specifications 22 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 74: ...12 Spare parts exploded view drawings 74 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 76: ...13 Decommissioning disposal 76 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 102: ...14 Appendix 102 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 103: ...Personal notes Reference Manual Edition 4 0 10 2013 EcoCut 3300 103 108...
Page 104: ...Personal notes 104 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 107: ......
Page 108: ......