14. Appendix
80|108
Reference Manual |Edition 4.0 (10-2013) |EcoCut 3300
D-Sub 15-pin (F)
HS/PF interface
PFPRESENT
PreFeeder
PFOUT
+24 VDC
S1
PFREADY
GND
Fig. 8: Connecting a PreFeeder
Input „PFREADY“, Pin 10 & 11:
If the D-sub connector is plugged in and the control contact S1 closed, the machine can be started nor-
mally. By opening the contact S1 the automatic operation is interrupted and the error message "PreFeed-
er blocked" is shown up on the display. After closing the contact S1 again, the program can be continued
with
[RUN]
.
Output „PFOUT“, Pin 14 & 15:
This output is set to open collector (ground potential) during processing. This means the output is held
active. It is dimensioned for inductive loads up to 0.2 A at 24 VDC (relays, valves) and is protected against
stress peaks.
14.2.2
For use with a HotStamp
The
Schleuniger
HotStamp devices are shipped with their appropriate connection cable. As per the follow-
ing diagram, the D-sub-connector can be self-wired by a qualified technician.
Summary of Contents for EcoCut 3300
Page 8: ...Table of contents 8 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 22: ...4 Product specifications 22 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 74: ...12 Spare parts exploded view drawings 74 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 76: ...13 Decommissioning disposal 76 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 102: ...14 Appendix 102 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 103: ...Personal notes Reference Manual Edition 4 0 10 2013 EcoCut 3300 103 108...
Page 104: ...Personal notes 104 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 107: ......
Page 108: ......