NPN outputs
The NPN outputs are internally protected against over temperature and electrostatic discharge. Short cir-
cuit and overload protection is handled directly through the over temperature protection circuitry. The
outputs are able to control ohmic and inductive loads.
Output
Safety
Circuit
Fig. 14: Principle schematic diagram of the NPN outputs
Parameter
Max. ratings
Min.
Typ.
Max.
Output signal
V
OH
V
OL
I
OUT
∼
0 mA
I
OUT
≤
- 300 mA
-
0.6
-
-
1.2
V
V
Output current
I
OUT
I
OUT_TOT
All outputs
a
-
-
-
-
- 300
- 1,80
mA
A
Max. switching frequency
f
MAX
-
-
1000
Hz
Short circuit current
b
I
OUT_SC
- 0,4
-
- 1,0
A
Response time of the short cir-
cuit protection
t
SC
-
-
-
ms
Impulse withstand voltage
V
OUT_SRG
I
OUT_SRG
≤
300 mA
t
OUT_SRG
≤
100 µs
- 0,3
-
60
V
a ) The sum of all the output currents of the NPN outputs must not exceed this value.
b ) The NPN outputs are thermally protected against short circuit.
Synchronization signal
Synchronization signals are transmitted differentially according to standard ANSI TIA/EIA-422 (formerly
known as RS422). The signal behavior is based on the signals of an incremental encoder. The signals are
provided directly from the motor control circuit in the machine. The impulse frequency is proportional to
the feed rate of the
EcoCut 3300
. The feed direction (forward / backward) can be recognized by means of
the signal phasing.
The synchronizing signals of the PREFEED interface are synchronized on the left transport unit. E. g. if the
left transport unit stands still, no pulses are transmitted even if the right transport unit is moving. The
synchronizing signals of the "POSTFEED" interface are synchronized on the right transport unit ("LENCB",
"RENCA" and "RENCB" are identical).
Summary of Contents for EcoCut 3300
Page 8: ...Table of contents 8 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 22: ...4 Product specifications 22 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 74: ...12 Spare parts exploded view drawings 74 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 76: ...13 Decommissioning disposal 76 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 102: ...14 Appendix 102 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 103: ...Personal notes Reference Manual Edition 4 0 10 2013 EcoCut 3300 103 108...
Page 104: ...Personal notes 104 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 107: ......
Page 108: ......