6 Installation
Operating Instructions | Version 1.0 (05-2018) | Uni-M Ferrule
22 | 32
(Note: Refer to Appendix A for instructions on
using the Panduit adjustment blocks.)
5.
Loosen the lock screw (1).
6.
Turn the positioning knob (2) to re-position the
terminal.
a.
Counterclockwise
increases the feed and
will move the terminal further
to the
right
.
b.
Clockwise
decreases the feed and will
move the terminal further
to the left
.
7.
Tighten the lock screw (1) and cycle the press
to test. Re-adjust as necessary.
8.
When the ferrule advances, it will be slightly
above the crimp anvil but not completely
centered over it as seen in Fig. 1.
9.
The cut-off blade (4) comes down, and pushes
the ferrule into the cavity (5) as seen in Fig.2.
10.
The blade cuts through the insulation and the
pusher blade (6) pushes the ferrule into the
cavity (5) and hold it in place as seen in Fig. 3.
6.2.4
Feed timing and rate adjustment
1.
The feed timing is automatically controlled by
the feed cam so adjustment is limited.
2.
The pneumatic cylinder rate can be adjusted
with the valves show.
a.
Counterclockwise increases feed rate.
b.
Clockwise reduces feed rate.
6.2.5
Funnel adjustment
1.
When the funnel is properly adjusted, it should
not be possible to see the edges of the ferrule
insulation when looking into the funnel.
2.
Funnels can be adjusted both horizontally and
vertically.
1
2
5
4
Fig. 1
6
Fig. 3
Fig. 2
1
Correct
Incorrect